- Thesystemhasathermalelementthatwillshutofftheflowofgasintheeventofafire.
- Thesystemhasaflowlimitingdevicewhich,whenactivated,willlimittheflowofgasto10cubicfeetper
hour.
- NEVERusesideburnerwithoutleaktestingthisconnection.
LP(Propane)GasSupplyConnection
1. The tank valve should be in the “OFF” position. If not, turn the knob
clockwiseuntilitstops.
2. Makesureallburnervalvesareinthe“OFF”position.
3. Alwaysconnectthegassupplyregulatorasfollows:
Inserttheregulatorinletintothetankvalveandturnthecoupling nut
clockwiseuntilthecouplertightensup(seepicture).Donotover‐tightenthe
coupler.Turnthemaintankvalveon,andturntheburnercontrolvalveson
theunittothe“HIGH”positionforabout20secondstoallowtheairinthe
systemtopurgebeforeattemptingtolighttheburners.
Pre‐OperationLeakTesting
1. Donotinsertanytoolintothevalveoutletorsafetyreliefvalve.Youmaydamagethevalveandcausea
leak.Leakingpropanemayresultinexplosion,fire,severepersonalinjury,ordeath.
2. Ifaleakisdetectedatanytime,oryoucannotstopagasleak,immediatelyclosethetank’sshut‐offvalve
(gassupplyfromLPtanktotheSideburner)andcallLPgassupplieroryourfiredepartment!
3. Checkallgassupplyfittingsbeforeeachuseandeachtimethegassupplycylinderisconnectedtothe
regulator.Haveaqualifiedservicetechnicianleaktestthesideburneranytimeapartofthegassystemis
replaced.
Neverattempttoattachthissideburnertotheself‐containedLPgassystem.Donotusethesideburneruntil
leaktestinghasbeencompleted.
LeakTestingValves,HoseandRegulator
1. NEVERsmokewhileleaktesting.
2. Extinguishallopenflames.Neverleaktestwithan
openflame.
3. Mixasolutionofequalpartsmilddetergentorliquid
soapandwater.
4. TurnallsideburnercontrolknobstoOFF.
5. Ensurethattheconnectionsfromtheregulatortothe
side burner and tank are tight and secure (see
picture).
6. Completely open LP tank valve by turning cylinder