Manual
10
- Thesystemhasathermalelementthatwillshutofftheflowofgasintheeventofafire.
- Thesystemhasaflowlimitingdevicewhich,whenactivated,willlimittheflowofgasto10cubicfeetper
hour.
- NEVERusesideburnerwithoutleaktestingthisconnection.
LP(Propane)GasSupplyConnection
1. The tank valve should be in the “OFF” position. If not, turn the knob
clockwiseuntilitstops.
2. Makesureallburnervalvesareinthe“OFF”position.
3. Alwaysconnectthegassupplyregulatorasfollows:
Inserttheregulatorinletintothetankvalveandturnthecoupling nut
clockwiseuntilthecouplertightensup(seepicture).Donotover‐tightenthe
coupler.Turnthemaintankvalveon,andturntheburnercontrolvalveson
theunittothe“HIGH”positionforabout20secondstoallowtheairinthe
systemtopurgebeforeattemptingtolighttheburners.
Pre‐OperationLeakTesting
1. Donotinsertanytoolintothevalveoutletorsafetyreliefvalve.Youmaydamagethevalveandcausea
leak.Leakingpropanemayresultinexplosion,fire,severepersonalinjury,ordeath.
2. Ifaleakisdetectedatanytime,oryoucannotstopagasleak,immediatelyclosethetank’sshut‐offvalve
(gassupplyfromLPtanktotheSideburner)andcallLPgassupplieroryourfiredepartment!
3. Checkallgassupplyfittingsbeforeeachuseandeachtimethegassupplycylinderisconnectedtothe
regulator.Haveaqualifiedservicetechnicianleaktestthesideburneranytimeapartofthegassystemis
replaced.
Neverattempttoattachthissideburnertotheself‐containedLPgassystem.Donotusethesideburneruntil
leaktestinghasbeencompleted.
LeakTestingValves,HoseandRegulator
1. NEVERsmokewhileleaktesting.
2. Extinguishallopenflames.Neverleaktestwithan
openflame.
3. Mixasolutionofequalpartsmilddetergentorliquid
soapandwater.
4. TurnallsideburnercontrolknobstoOFF.
5. Ensurethattheconnectionsfromtheregulatortothe
side burner and tank are tight and secure (see
picture).
6. Completely open LP tank valve by turning cylinder