Manual
12
- ExchangeyourType1cylinderforOPDsafetyfeature‐equippedreplacementtankONLY.
- AlwayskeepnewandexchangedLPtanksinuprightpositionduringuse,transitorstorage.Leaktestnew
andexchangedLPtanksBEFOREconnectingtosideburner.
LargeCapacityPropaneTanksandHomes:
Ifyourentirehouseisplumbedforpropanegasuse,andyouhaveanexteriorconnectionforsuchuse,
thenastandardLPsideburnerfromCoyotecanbeconnectedtosuchoutdoorpropaneconnection,but
youmustbeawareofthefollowing:
o Coyotedoesnotsupplyanygasfittingsorlines,otherthantheregulatorneededwithintheside
burnerbox
o AllCoyoteLPSideburnerscomewitha20lbtankregulator.Thisregulatorcannotbeusedor
modifiedtoworkonanyothersetup.
Ifyouarerunningoffofalargecapacitytank(morethan
20lbs), then an “in‐line” LP regulator is needed, which can be purchased from any
Coyote authorized dealer, or plumbing supply company. However, it is the
responsibilityoftheowner/installertoverifythatthecorrectregulatorispurchasedfor
theintendedapplicationandthatitisinstalledproperly.
o Ascodesvaryfromstatetostate,itistheresponsibilityoftheowner/installertoensurethatall
county,stateandfederalcodesarefollowedforanygasinstallation.
-
Alwayschecktheratingplatetomakesurethegassupplytowhichyouconnectthesideburneristhegastype
thesideburnerismanufacturedfor.
ACoyotenaturalgas(NG)sideburnerisdesignedtooperateonnaturalgasONLY,
atapressureregulatedat4”(101.6mm)watercolumn(W.C.)when equipped with the correct natural gas
orificesonthevalvesandanaturalgasregulatoronthesupplylineregulatedattheresidentialmeter.
Neverconnectthesideburnertoanunregulatedgassupply.
NATURAL GAS CONNECTIONS MUST BE PERFORMED BY A LICENSED CONTRACTORORLOCALGASCOMPANY
REPRESENTATIVE.
NaturalGasRegulator
NEVERusesideburnerwithoutleaktestingthisconnection.
Naturalgasregulatormodel:GR120
Gaspressure:4”(101.6mm)
Maximumrateworkingpressure:1/2Psig
Natural Gas Supply