Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill is
manufactured for.
This natural gas grill is designed to operate on natural gas ONLY, at a pressure regulated at 4” (101.6mm) water
column (W.C.) when equipped with the correct natural gas orifices on the valves and a natural gas regulator on
the supply line regulated at the residential meter.
IMPORTANT: Never connect the grill to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company representative.
Natural Gas Regulator
IMPORTANT: NEVER use grill without leak testing this connection.
Natural gas regulator model: GR120
Gas pressure: 4” (101.6mm)
Maximum rate working pressure: 1/2 Psig
Natural Gas Supply and Connection
1. Make sure all burner valves are in the “OFF” position
2. All NG units need to have a regulator and shut-off valve on the supply line.
3. All Pipe threads need to have proper, gas rated, outdoor rated thread sealant. Flare ends do not need or
utilize pipe sealant.
4. Your NG Coyote grill comes with a ½” regulator
a) You need to seal the regulator to the hose using your pipe sealant.
b) Then attach the flare end to your manifold line, with no pipe sealant.
c) Next, attach your next connection hose (not included) to the other side of the NG regulator (it is also
½” MIP)
i. We suggest using ½” stainless steel corrugated hoses for all NG Grills
ii. Make sure that you purchase a hose of adequate length and capacity for the intended
application.
d) Connect the other end of this hose, to your shut off valve
i. Depending on your choice of hose and shut-off, the nipple going into the shut-off valve may
vary.
e) Test all connections for leaks with a soap and water solution.
Natural Gas Hook-up