LPTankFilling
- Useonlylicensedandexperienceddealers.
- LPdealermustpurgedtankbeforefilling.
- DealershouldNEVERfillLPtankmorethan80%ofLPtankvolume.Volumeofpropaneintankwillvaryby
temperature.
- A frosty regulator indicates gas overfill. Immediately close LP tank valve and call local
LP gas dealer for
assistance.
- Donotreleaseliquidpropane(LP)gasintotheatmosphere.Thisisahazardouspractice.
- Toremovegas from LP tank,contactanLPdealerorcall alocal fire department for assistance.Check the
telephonedirectoryunder“Gascompanies”fornearestcertifiedLP
dealers.
LPTankExchange
- ExchangeyourType1cylinderwithOPDsafetyfeatureequippedONLY.
- Alwayskeepnew and exchanged LPtanksinuprightpositionduringuse,transitorstorage.Leaktestnew
andexchangedLPtanksBEFOREconnectingtoburner.
LargeCapacityPropaneTanksandHomes:
LP (Liquid Propane) Coyote Grills can be installed into propane fueled houses. Meaning that if your
entirehouseisplumbedforpropaneandyouhaveanexteriorconnectionforsuchuse,thenastandard
LPsideburnerfromCoyotewillmeetyourneeds,regardlessofthesize.Anyappliancecan
beinstalledif
installedproperly!ThatistheCoyoteway!
o Coyotedoesnotsupplyanygasfittingsorlines,otherthantheregulatorneededwithinthegrill
box
o All Coyote LP Side burnerscomewitha20lbtank regulator. This regulatorcannot be used or
modifiedto
workonanyothersetup.
If you are running off of a large capacity tank (more than 20lbs), then an “inline” LP
regulator is needed, Coyote Customer Service must be contacted to assist with this
situation.
o As counties vary from state to state, it is upon the owner/installer
to ensure that all county,
stateandfederalcodesarefollowedforanygasinstallation.
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill is
manufacturedfor.
ThisnaturalgassideburnerisdesignedtooperateonnaturalgasONLY,atapressureregulatedat4”(101.6mm)
water column (W.C.) when equipped with the correct natural gas orifices on the valves and a natural gas
regulatoronthesupplylineregulatedattheresidentialmeter.
IMPORTANT:Neverconnectthegrilltoanunregulatedgassupply.
Naturalgasconnectionsmustbeperformedbyalicensedcontractororlocalgascompanyrepresentative.
Natural Gas Hook-up