Owner's Manual
7
This propane gas side burner is designed to operate on propane gas ONLY, at a pressure regulated at
11”(279.4mm) water column (W.C.) when equipped with the correct propane orifices on the valves and a
propaneregulatoronthesupplylineregulatedattheresidentialmeter.TheLPgassideburnerisdesignedtobe
usedwithastandard20lbsgascylinderandmustbeconstructedandmarkedinaccordancewithspecifications
oftheUSDepartmentofTransportationforpropanegascylinders.
Always keep cylinder securely fastened in an upright position. Never connect an unregulated propane gas
cylindertothesideburner.
Donotsubjectpropanecylinderstoexcessiveheat.
CAUTION:NeverstoreaLPgascylinderinsideabuildingorinthevicinityofanygas‐burningappliance.
Cylinder Specifications
- Any L.P. gas supply cylinder used with this appliance must be approximately 12 inches diameter and 18
inches high. The maximum fuel capacity is 80% and is approximately 20
poundsofpropane.
- The L.P. cylinder must have a shut‐off valve (see picture) terminating in a
Type1L.P.
-
AType 1compatiblecylinderwith aType1cylindervalvehasa back‐check
valve which does not permit gas flow, until a positive seal has been
obtained.
- Thecylindermustbearrangedfor vapor withdrawal. It mustalsoincludea
collar to protect the cylinder valve. A safety
relief device having direct
communicationwiththevaporspaceofcylindermustbeprovided.Thiswill
expel high pressure gas if the cylinder is overfilled or overheated which
couldresultinfireorexplosion.
- All L.P. gas cylinders used with this appliance shall be constructed and marked in accordance with
the
specifications for L.P. gas cylinders of the U. S. Department of Transportation (DOT) or the National
StandardofCanada,CAN/CSA‐B339,Cylinders,SpheresandTubesforTransportationofDangerousGoods;
andCommission,asapplicable;andshallbeprovidedwithalistedoverfillingpreventiondevice.
- ReadlabelsontheL.P.
GasSupplyCylinder.
- Newcylindersarealwaysshippedemptyforsafety.
- AllowonlyqualifiedL.P.gasdealerstofillorrepairyourL.P.gassupplycylinder.
- Informthegasdealerifitisaneworusedcylindertobefilled.
- Afterfilling,havethegasdealercheck
forleaksandtoseethatthereliefvalveremainsfreetofunction.
LP Gas Hook-up