combustible material without an approved ventilation system directly located above the unit.
For Built-in Installations
A built-in power burner is designed for easy installation into masonry enclosures. For non-combustible
applications, the power burner drops into the opening (as shown in cut-out detail drawing - Fig. A)
and hangs from the power burner body itself. A bottom deck is not required to support the power burner
from the bottom. It is also required that:
Two ventilation holes, of at least 20 sq inches in size, must be present to help release any gas
from a leak and allow residual heat to dissipate.
The counter should be flat and level in reference to the floor.
LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT OF THE
POWER BURNER AND IT MUST BE VENTED AS WELL. (RECOMMEND BOTTOM VENTS FOR LP)
Cut out Dimensions Figure A
Model
Product
Description
Cutout Dimensions Overall Dimensions
Total BTU
Ratings
Electrical
Outlets (110V)
Height
Width
Depth
Height
Width
Depth
LP NG Qty Needed
CPB Power Burner 11 1/2" 21" 22 1/2" 12 3/4" 24" 26" 60,000 60,000 No Electrical