Full Product Manual

1018454-EPage 21
STARTINGPILOTPROSYSTEMPERANSIZ21.71
STEP5.
Re-install the heater door on the front of the
housing, at the base.
STEP3.
STEP4.
Determine that the pilot is igniting and burning properly and that
main burner ignition is satisfactory by turning the thermostat
off and back on. Make this determination with the appliance
burner both cold and hot. Perform this step as many times as is
necessary to satisfy yourself that the automatic intermittent pilot
system is operating properly.
- Sequence the appliance through at least three (3)
operating cycles.
- Check all furnace connections for gas leaks with leak
detector solution, including plug installed into valve body.
Donotuseopename.
!
EnsureIgnitorsparksonly
againstthehoodofthepilot.
Ignitor should not spark against the ame sensor, brackets, heating
chamber, burner, etc. Adjust ignitor probe location if required.
- DO NOTtwistignitorwireorbreakfromceramicbase.
- DO NOTuseabrokenignitor.