 BDOS FUNCTION 41: TEST AND WRITE RECORD
 Entry Parameters:
 Registers C: 29H
 DE: FCB Address
 Returned Value:
 Registers A: Error Code
 H: Physical Error
 The Test and Write Record function is an MP/M 11" function that is not sup-
 ported under CP/M 3. If called, Function 41 returns with register A set to OFFH and
 register H set to zero.