2.0 General Infomation
The CPI TTP(N) series termination panels provide a reliable means of interfacing a tone remote to a two way
radio base station. The TTP series can be used with any tone remote that uses the industry standard EIA se-
quential tone format such as the CPI TR series remotes. The TTP(N) series panels are available in the following
congurations.
MODEL DESCRIPTION
TTP1(N) Board only single frequency, PTT, and monitor
TTP2(N) Board only two frequency, PTT, and monitor
-C(TTPN) Case option for the TTP(N)
There are no other options available for the TTP(N) series panels. Jumper selectable -4W/FD is standard as
well as automatic gain control and transmit and receive audio notch lters.
3.0 Installation
Connect the leased line, twisted pair 600 ohm line, or microwave link to the TTP(N) board via J2 (RJ-11 jack).
Connect an external 12 to 16 volt semi-regulated DC power supply to J1 with the positive lead to J1-2 and the
negative lead to J1-7.
Connect the receive audio from the radio to J1-6. Receive audio from the radio should be a source that is after
the squelch circuit and not affected by the radio volume control adjustment. If such as point is not easily acces-
sible you may use unsquelched audio and use the squelch circuit provided on the TTP(N).
Connect the radio microphone input to J1-1. If the microphone input is high impedence, shielded cable should
be used and jumper JP3 on the TTP(N) board should be moved to the 2&3 position.
Connect the monitor circuit of the radio to the TTP(N) board using the form “C” relay contacts at J1-8, J1-9,
and J1-10.
Connect the radio PTT line to the TTP using the contact provided at J1-4. Jumper JP7 allows you to select “key
to ground” shorting pins 1&2 or “key to + voltage” shorting 2&3.
The TTP2(N) provides momentary or latched set of form “C” relay contacts for two frequency selection. Jump-
er JP14 in position 1&2 is for latching. Position 2&3 is momentary operation.
2 Wire/4 Wire Full Duplex operation
The TTP(N) termination panel is 2 wire/ 4 wire full duplex capable by selection of the JP1 jumper on the panel.
2 Wire - Jumper JP1 should be in the 1 & 2 position
4 Wire/ Full Duplex - Jumper JP1 should be in the 2 & 3 position
3