Instruction Manual TTP216 Series Multi-Frequency Tone Termination Panel 1/2013 CPI Communications 941 Hensley Lane Wylie, Texas 75098 Phone (972)429-7160 (800)869-9128 Fax (972)429-7165 (888) 437-5360 www.cpicomm.
TTP216 Specifications Specifications: Subject to change without notice Size: 5.5" wide 1.5" high 7.5" length Weight: 1.6 lbs. Connections: modular and screw terminals to phone line (remote) modular and screw terminal to radio modular desk microphone connection Input voltage: +12 to +13.8 VDC @150mA (18 mA idle) Line impendence: 600 ohms Line output to phone line +10 dBm max.
I. Connectors connector location J1 front panel connects to local mic when modular interconnection configuration is used function J2 front panel connects to radio when modular interconnection configuration is used J3 back panel connects to remotes J4 board, rear auxiliary 2-wire or 4-wire RX connection to remotes auxiliary 12 Volt D.C.
III. Front Panel Indicators indicator color PTT red function MON green Monitor on F1 yellow F1/BCD0 output on (open collector low) F2 yellow F2/BCD1 output on (open collector low) F3 yellow F3/BCD2 output on (open collector low) F4 yellow F4/BCD3 output on (open collector low) F5 yellow F5/BCD4 output on (open collector low) PTT on IV.
JP5 Squelch Control Mode Selects Squelch Control input logic level 1-2 (default) mute RX Audio when input low 2-3 mute RX Audio when input high JP6 Selects automatic Monitor with all remote PTT's 1-2 (default) automatic monitor disabled 2-3 automatic monitor enabled RX Audio Gain Selects gain of the RX Audio amplifier 1-2 (default) selects low gain 2-3 selects high gain JP7 JP11 Monitor With PTT JP12 Monitor Mode Selects duration of monitor output 1-2 (default) latched -- on with Monitor
VI. J1 and J2 Configuration Settings Jumper groups E1-x and E2-x directly enable configuration of the J1 and J2 connectors. Alternatively, connectors E1 and E2 can be manually wired in any configuration.
B. Options The TTP200 is programmed by selecting a pre-programmed "EIA Tone-to-Output" assignment pattern, or "Pre-Set." Pre-Sets are available for several different output options: 1. Discrete 1 of 5 Outputs Pre-Sets 1 through x assign the 16 standard EIA tones to activate one, and only one, of the "Fx" outputs at a time. 2.
3. To Check the Existing Program: OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON 8 7 6 5 4 3 2 1 Y X F5 F4 F3 F2 F1 PROG a. Turn the PROG switch ON. b. During the first three seconds, the ABCD LED’s indicate the number of the currently loaded Pre-Set in binary form. This indication flashes if the PRE-Set has been customized. c. After the ABCD LED’s go out, switches F1 through F5 can be used to select a specific output to be checked. d.
5. To Customize the Existing EIA Tone-to-Output Assignment: OFF ON OFF OFF OFF OFF OFF ON ON ON ON ON ON 8 7 6 5 4 3 2 1 Y X F5 F4 F3 F2 F1 PROG A customized EIA Tone-to-Output Assignment is created by first loading a standard Pre-Set, then re-assigning as many outputs as desired to new EIA Tone values. It is also possible to un-assign outputs from the loaded Pre-Set. Blank Pre-Sets are available for use in building a customized EIA Tone-to-Output pattern “from scratch.” a.
Example2: Un-Assign A Discrete Split Output from Its EIA Tone After loading Pre-Set #5: a. Turn the Y switch ON. b. Turn the PROG switch ON. c. Turn the F2 switch (S2-3) ON and switches F1 (S2-2) and F3 through F5 (S2-4 through S2-6) OFF. d. With the 1850 EIA Tone LED lit, press and release the Tone Select pushbutton until the “450” EIA Tone LED goes out and no other EIA Tone LED’s are lit. e. Turn the Y switch OFF. f. Turn the PROG switch OFF. g.
D.
Blank Pre-Set #7 is provided to facilitate building up a Discrete Split Output set “from scratch”: Pre-Set Number LED indication 7 A = on ! B = on ! C = on ! D = off # Output Line EIA Tone F1 - group a not assigned F2 - group a not assigned F3 - group a not assigned F4 - group b not assigned F5 - group b not assigned Discrete Wildcard Outputs – When an EIA Tone assigned to F1 through F4 is received, its Output is turned ON and all other F1 through F4 outputs are turned OFF.
Binary Four-Bit Outputs: Pre-Set Number LED indication 11 A = on ! B = on ! C = off # D = on ! Output Lines F1 F2 F3 F4 EIA Tone F5 0 0 0 0 0 1950 1 0 0 0 0 1850 0 1 0 0 0 1750 1 1 0 0 0 1650 0 0 1 0 0 1550 1 0 1 0 0 1450 0 1 1 0 0 1350 1 1 1 0 0 1250 0 0 0 1 0 1150 1 0 0 1 0 1050 0 1 0 1 0 950 1 1 0 1 0 850 0 0 1 1 0 750 1 0 1 1 0 650 0 1 1 1 0 550 1 1 1 1 0 450 Pre-Set Number LED indication A = off
Binary Five-Bit Outputs: Pre-Set Number LED indication A = on ! B = off # C = on ! D = on ! 13 Output Lines F1 F2 F3 F4 EIA Tone F5 1 0 0 0 0 1950 0 1 0 0 0 1850 1 1 0 0 0 1750 0 0 1 0 0 1650 1 0 1 0 0 1550 0 1 1 0 0 1450 1 1 1 0 0 1350 0 0 0 1 0 1250 1 0 0 1 0 1150 0 1 0 1 0 1050 1 1 0 1 0 950 0 0 1 1 0 850 1 0 1 1 0 750 0 1 1 1 0 650 1 1 1 1 0 550 0 0 0 0 1 450 Pre-Set Number LED indication A = off #
Blank Pre-Set #15 is provided to facilitate building up a Binary Output set “from scratch”: Pre-Set Number LED indication A = on ! B = on ! C = on ! D = on ! 15 Output Lines F1 F2 F3 F4 EIA Tone F5 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0 not assigned 0 0 0 0 0