CC240RF COMPUTE-A-CHARGE® WIRELESS CHARGING SCALE OPERATION MANUAL
GENERAL INFORMATION Table of Contents General Information Charge Mode 2 Operation Recovery Mode 3-9 Key Funtions Additional Features 3 Display Screens 3-5 Weigh Mode 5 6 6-7 7 Troubleshooting 8-9 Warranty 10 The CC240RF is an advanced, battery operated, WIRELESS weighing and charging scale. It has been designed to be accurate, rugged and reliable over a large weighing span (240 lbs / 110 kg).
OPERATION Key Functions NOTE: Every key press received by the scale platform is acknowledged with a beep. If you have lost connectivity, there will be no beep from the scale platform and the display may freeze. It will be necessary to re-enter the key stroke when you are within range and connectivity is restored. POWER [ ]: Turns the display and control unit as well as the weighing platform ON or OFF. Press once to turn power ON, if the display and control unit is OFF.
OPERATION Figure - 1: Displays the software version of the unit. Figure - 2: Automatic Power Off enabled. Press [TARE] key to change. (See page 8 for details) Figure - 3: Shows the display and control unit battery voltage. Figure - 4: Count down to connect with the scale platform on channel 0. Figure - 5: Connection established. Displays software version of scale platform. Figure - 6: Scale platform Automatic Power Off status.
OPERATION Figure - 7: Scale platform battery voltage. Figure - 8: Notifies the user that a zero calibration is being performed. Figure - 9: Notifies the user that a full scale calibration is being performed. Figure - 10: Instrument is ready to be used. Weigh Mode 1. Place the weighing platform on a level, rigid surface. ] key to turn the unit ON, any 2. Press POWER [ weight on platform will be set to zero. (See figures 1-10 for the screen squence while CC240RF turns on). 3.
OPERATION Charge Mode 1. Place the weighing platform on a level, rigid surface. Figure - A ] key to turn the unit ON any 2. Press POWER [ weight on platform will be set to zero. (See figures 1-10 for the screen squence while CC240RF turns on). 3. Select the desired units by pressing [LB / KG] key. 4. Place cylinder on scale and connect scale as shown in Figure-A. The display will show the weight of the Freon® plus the weight of the cylinder. Press [TARE] to zero the scale platform. 5.
OPERATION Danger - the recovery cylinder used contains liquid refrigerant. Overfilling of the recovery tank may cause a violent explosion resulting in severe injury or even death. 6. Turn on the refrigerant recovery unit. Follow the recovery unit’s instructions. 7. If the recovery process finishes before the weight reaches the maximum tank fill weight, close the cylinder valve and all other valves that are in the recovery pathway. (Go to step #10) 8.
OPERATION Troubleshooting The CC240RF has been designed with the rough conditions of service work in mind. However, it is a precision instrument and, as such, certain precautions need to be observed to enjoy the benefits of its performance for a long time. 1. Control and display unit does not turn on: a. Check for dead batteries. b. Check for reversed polarity. c. Remove 9 volt alkaline battery for one minute; replace battery, listening for the battery installed tones.
OPERATION reading is 7.00 VDC, although useful operation can be obtained with battery voltages all the way to 6.00 VDC. During operation, the amount of battery life remaining will be displayed in the battery symbol on the display. When the battery is correctly installed, you will hear 2 tones followed by 5 faster tones. After the control and display unit connects with the scale platform, the voltage of the battery pack in the platform will be shown on the display (See Fig. 7).
WARRANTY CPS® Products, Inc. guarantees that all products are free of manufacturing and material defects to the original owner for one year from the date of purchase. If the equipment should fail during the guarantee period it will be repaired or replaced (at our option) at no charge. This guarantee does not apply to equipment that has been altered, misused or solely in need of field service maintenance. All repaired equipment will carry an independent 90-day warranty.
NOTES