Technical data

55
4. MPPTCycle” is used to set up the cycle time of MPPT Scan. Move the
cursor to this menu, press ENT to set up the cycle time. Use UP and DOWN to
adjust the MPPT cycle time. Press ENT to confirm the setting.
5. “MPPTScan” is to execute the MPPT scanning manually. Move the
cursor to this menu, and press ENT to initiate the scanning. The LCD screen
will skip to normal operation interface if the MPPT scanning succeeds, but
remain on the “MPPTScan menu” interface if the scanning fails.
(7) Configure the network address in the “7 NetConfig” menu.
Move the cursor to the menu, press ENT and set up the parameters by
UP and DOWN.
5.4.5 Power dispatch
Move the cursor to “5 Dispatch” in the main interface and press ENT to go
to the following interface (Figure 5-13):
5 Dispatch
ActivePower(%)
100.0
PowerFactor
1.000
Figure 5-13 Active Power and PowerFactor
Remote power dispatch: The “ActivePower” and “PowerFactor” can be
adjusted remotely by software.
INSTRUCTION:
Move the cursor to the corresponding menu to set up the
parameters, and the number will flash after pressing ENT. Use UP
and DOWN to adjust the parameters.