Technical data

6
2 MPPTs: Dual and independent MPPT (Maximum Power Point Tracking)
enable maximum design flexibility and optimize energy harvest over the life
of the system
High protection degree: NEMA 4 protection degree meets the needs of
both indoor and outdoor use;
Intelligent Integration: Embedded DC/AC switches and up to 8 fused
string inputs eliminates the need for external combiner boxes and
simplifies installation.
2.3 Product protection functions
Polarity reverse protection of DC input
Short circuit protection
DC input insulation against ground monitoring
AC output voltage and frequency monitoring
Leakage current against ground monitoring
Monitoring of DC injection from AC output
Anti-islanding protection
Input and output over-voltage protection
Input over-current protection
Environmental temperature monitoring
Module temperature monitoring
2.4 Circuit structure design
The basic schematic diagram of CPS SCA23/28KTL-DO/US-480 series
inverter is shown in Figure 2-2.
The input of PV modules passes through surge protection circuitry, DC
EMI wave filter, and the front-end boost circuitry to achieve maximum power
tracking and boost up voltages. The output of the inverter converts the DC
voltage to 3-phase AC voltage. The high frequency AC components are