NOTE: Only one operation is supported at a time. If you try to start the same operation on the same modem twice the UI
will not report failure and the request will finish normally when the original request is done. However if you try to start a
different operation or use a different modem, this second request will fail without interfering with the pending operation.
Process Timeout: If the process fails an error message will display.
Activation has a 3-minute timeout, PRL update has a 4-minute timeout, and FUMO has a 10-minute timeout.
Update Modem Firmware
Click on the Firmware button to open the Modem Firmware Upgrade window. This will show whether there is new
modem firmware available.
If you select Automatic (Internet) the firmware will be updated automatically. Use Manual Firmware Upgrade to
instead manually upload firmware from a local computer or device.
Reset the Modem
Click on the Reset button to power cycle the modem. This will have the same effect as unplugging the modem.
Configuration Rules (Advanced)
This section allows you to create general rules that apply to the Internet connections of a particular type. These can be
general or very specific. For example, you could create a rule that applies to all 3G/4G modems, or a rule that only
applies to an Internet source with a particular MAC address.
131