User manual
20 
MAIN TABLE TO BLADE 
PARALLELISM 
Your  CX202  will give a better result if the 
main table is parallel to the blade. If it is not 
parallel, the result you will get will be poor 
and low quality. 
To check if the table is parallel to the blade, 
use an adjustable square and measure the 
distance between the miter slot on the table 
and the edge of the blade (front or back) as 
shown in figure-32. 
Figure-32 Measuring the distance using an 
adjustable square 
Now, lock the square in place and mark the 
blade  with a marker where you made the 
measurement. Rotate the blade so that the 
mark is opposite to the first position (front or 
back)  and slide the square to check if the 
blade is at the same distance with the miter 
slot.  
The measurement should be equal on both 
sides. If the measurements are not the 
same, the table needs to be adjusted 
parallel to the blade. 
To adjust the table: 
Make sure the switch is in the “OFF” 
position and the cord is unplugged from the 
power source. 
Loosen the four mounting bolts (shown in 
figure-33) securing the table on the cabinet 
and  adjust  the table to get equal 
measurements on both sides of the blade. 
Once the table is parallel to the blade, re-
tighten the mounting bolts. 
Figure-33 Mounting bolts location 
SPREADER AND RIVING 
KNIFE ALIGNMENT 
The blade guard spreader and riving knife 
must be aligned with the blade for safe and 
accurate cutting operation. If the blade 
guard spreader or the  riving knife is not 
aligned  with the blade, the work-piece will 
be pushed sideways during operation and 
increasing the risk of kick back. 
Make sure the switch is “OFF” and check 
the spreader or riving knife alignment using 
a straight-edge. Raise the blade to the 
maximum height using the blade height  