User manual

8
Figure-3 Inventory
LIST OF CONTENTS QTY
Q. Legs ................................................ 4
R. Brackets .......................................... 4
S. Feet ................................................. 4
T. Hardware Bag ................................. 1
PROPER GROUNDING
Grounding provides a path of least
resistance for electric current to reduce the
risk of electric shock.
CX202 is equipped with a 120-Volt, single
phase motor which features a 3-conductor
cord and a 3-prong grounded plug to fit a
grounded type receptacle. Do not remove
the grounding prong to fit it into a 2-pronged
outlet. Always check with a qualified
electrician if you are in doubt. Make sure
the cord is plugged into a properly installed
and grounded power outlet.
To prevent electrical hazards, have a
qualified electrician ensure that the line is
properly wired.
This tool is for use on a normal 120-volt
circuit and is factory-equipped with a
specific electric cord and plug to permit
connection to a proper electric circuit. Make
sure that the appliance is connected to an
outlet having the same configuration as the
plug. If an adaptor plug is used, it must be
attached to the metal screw of the
receptacle.
Figure-4 120-Volts Outlet for CX202
It is strongly recommended not to use
extension cords with your CX202. Always
try to position your machine close to the
power source so that you do not need to
use extension cords.
In case if you really find it necessary to use
an extension cord, make sure the extension
cord does not exceed 50-feet in length and
the cord is 14-gauge to prevent motor
damage.
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician if you are in doubt as to
whether the outlet is properly grounded.