User manual
8 
Figure-3 Inventory 
LIST OF CONTENTS    QTY 
Q.  Legs ................................................ 4 
R.  Brackets .......................................... 4 
S. Feet .................................................  4 
T.  Hardware Bag .................................  1 
PROPER GROUNDING 
Grounding provides a path  of least 
resistance for electric current to reduce the 
risk of electric shock.  
CX202 is equipped with a 120-Volt, single 
phase motor which features a 3-conductor 
cord and a 3-prong grounded  plug to fit a 
grounded type receptacle. Do not remove 
the grounding prong to fit it into a 2-pronged 
outlet. Always check with a qualified 
electrician if you are in doubt. Make sure 
the cord is plugged into a properly installed 
and grounded power outlet. 
To prevent electrical hazards, have a 
qualified electrician ensure that the line is 
properly wired. 
This tool is for use on a normal 120-volt 
circuit and is factory-equipped with a 
specific electric cord and plug to permit 
connection to a proper electric circuit. Make 
sure that the appliance is connected to an 
outlet having the same configuration as the 
plug.  If an adaptor plug is used, it must be 
attached to the metal screw of the 
receptacle. 
Figure-4 120-Volts Outlet for CX202 
It is strongly recommended not to use 
extension cords with your CX202. Always 
try to  position your machine close to the 
power source so that you do not need to 
use extension cords. 
In case if you really find it necessary to use 
an extension cord, make sure the extension 
cord does not exceed 50-feet in length and 
the cord is 14-gauge to prevent motor 
damage. 
WARNING 
Improper connection of the equipment-
grounding conductor can result in a risk 
of electric shock. Check with a qualified 
electrician if you are in doubt as to 
whether the outlet is properly grounded.  