Installation Guide

Please read carefully and save these instructions, as you may need them at a later date.
Turn off the main power at the circuit breaker before installing the fixture in order to prevent
possible shock.
All electrical connections must be in accordance with local and National Electrical Code (N.E.C.)
standards. If you are unfamiliar with proper electrical wiring connections, obtain the services of a
qualified electrician.
Remove all parts and hardware from the box and mounting package and make sure that none are
missing by referencing the illustrations provided.
1. Pull the SUPPLY WIRES (8 & 10) and the SUPPLY GROUND WIRE (7) out from the OUTLET BOX (1)
(not included) and attach the MOUNTING STRAP (2) assembly to the OUTLET BOX (1) using the slotted
holes of the MOUNTING STRAP (2) and the OUTLET BOX SCREWS and WASHERS (3). [See Fig. 1]
2. Remove the THREADED RING (16) from the SCREW COLLAR LOOP (5) and set aside. Place the
CANOPY (15) over the OUTLET BOX (1) and adjust the SCREW COLLAR LOOP (5) and THREADED
ROD (14) until the midpoint of the outside threads on the SCREW COLLAR LOOP (5) is centered
(aligned) with the surface of the CANOPY (15). Remove the CANOPY (15) and tighten both
HEX NUTS (4) down on the MOUNTING STRAP (2) and the SCREW COLLAR LOOP (5). [See Fig. 1]
3. Slide the FIXTURE LOOP (19) down the fixture wires and then thread into the coupling at the top of the
FIXTURE (21) until tight. Adjust the SCROLL ARMS (20) on the FIXTURE (21) so that they are level.
4. Attach one OPEN CHAIN LINK (18) to each end of the CHAIN (17). Then attach one end of the
CHAIN (17) to the FIXTURE LOOP (19). Slide the THREADED RING (16) and the CANOPY (15)
(in that order) onto the CHAIN (17) and attach the other end of the CHAIN (17) to the SCREW COLLAR
LOOP (5). Close the OPEN CHAIN LINKS (18). [See Fig. 1 & 2]
5. Unravel the FIXTURE LEAD WIRES (9 & 11) and FIXTURE GROUND WIRE (6) and thread them
through every other link of the CHAIN (17) starting with the chain link attached to the FIXTURE
LOOP (19). Feed the FIXTURE LEAD WIRES (9 & 11) and FIXTURE GROUND WIRE (6) through the
SCREW COLLAR LOOP (5) and THREADED ROD (14). Pull the FIXTURE LEAD WIRES (9 & 11)
and the FIXTURE GROUND WIRE (6) upward to remove any excess slack. [See Fig. 1]
6. Attach the power supply wires to the fixture lead wires by connecting the BLACK SUPPLY WIRE (8) to
the SMOOTH FIXTURE LEAD WIRE (9) and the WHITE SUPPLY WIRE (10) to the RIBBED
FIXTURE LEAD WIRE (11). Loop the SUPPLY GROUND WIRE (7) around the GROUND SCREW (13)
on the MOUNTING STRAP (2). [Note: Be sure to provide an extra 3in. length of the SUPPLY GROUND
WIRE (7) for connection to the FIXTURE GROUND WIRE (6).] Connect the remaining SUPPLY
GROUND WIRE (7) to the FIXTURE GROUND WIRE (6). Use a WIRE CONNECTOR (12) for all
wire connections. Push wiring and connections inside the OUTLET BOX (1). [See Fig. 1]
7. Slide the CANOPY (15) and the THREADED RING (16) up the CHAIN (17). Place the CANOPY (15)
over the OUTLET BOX (1) and secure by screwing the THREADED RING (16) onto the SCREW
COLLAR LOOP (5). [See Fig. 1]
# 28053-SPZ
GENERAL
ASSEMBLY AND INSTALLATION
CAUTION
FIG. 2
ASSEMBLY AND INSTALLATION (Continued)
8. Install bulbs, MAXIMUM 60W each.
9. Attach THREADED ROD (22) to the bottom of the FIXTURE (21) and secure with the (uppermost)
HEX NUT (22). Attach a GASKET (24) to the THREADED ROD (22), securing it with a HEX
NUT (23), then place the GLASS SHADE (25) and the other GASKET (24) onto the THREADED
ROD (22); secure with the other HEX NUT (23). Attach FINIAL PLATE (26) and secure with
FINIAL (27).
INSTALLATION IS NOW COMPLETE
3-LIGHT CONVERTIBLE (PENDANT)
1. OUTLET BOX (NOT INCLUDED)
2. MOUNTING STRAP
3. OUTLET BOX SCREW and WASHER
(pre-attached to outlet box)
4. HEX NUT
5. SCREW COLLAR LOOP
(pre-attached)
6. FIXTURE GROUND WIRE
7. SUPPLY GROUND WIRE (not included)
8. BLACK SUPPLY WIRE (not included)
9. SMOOTH FIXTURE LEAD WIRE
10.WHITE SUPPLY WIRE (not included)
11. RIBBED FIXTURE LEAD WIRE
12. WIRE CONNECTOR
FIG. 1
SEVILLE
Customer Service: 1 (800) 527-1292
9
8
7
10
12
1
11
6
3
13
4
2
4
14
18
16
15
5
17
18
13. GROUND SCREW
(pre-attached)
14. THREADED ROD
(pre-attached)
15. CANOPY
16. THREADED RING
17. CHAIN
18. OPEN CHAIN LINK
19. FIXTURE LOOP
20. SCROLL ARM
(pre-attached)
21. FIXTURE
22. THREADED ROD
and HEX NUT
23. HEX NUT
24. GASKET
25. GLASS SHADE
26. FINIAL PLATE
27. FINIAL
19
20
21
23
22
24
25
26
27

Summary of content (2 pages)