INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, away from moving parts of door and door
hardware. If installing into drywall, drill 5/32" holes and
use the anchors provided.
1. Strip 1/4" (6 mm) of insulation from one end of bell
wire and connect to the two terminal screws on
back of door control by color: white to 2 and
white/red to 1.
2. Door Control Button: Fasten securely with
screws 6ABx1-1/2".
3. (For standard installation only) Run bell wire up
wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
WARNING
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
Be sure power is not connected BEFORE installing door
control.
Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet (1.5 m),
and away from all moving parts of door.
NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
Terminal
Screws
Wire
2-Conductor Opener
Bell Wire Terminal Screws
(BACK VIEW)
DOOR CONTROL BUTTON
Back Panel
of Opener
17