Owner`s manual
Troubleshooting
Motor Problem
Motor overheats or stalls
While motor is running, fuses
blow
Possible Cause(s)
Overloaded power line
Feeding rote too fast
Improper motor cooling
Saw blade "hasheel
Saw blade is dull
Motor Overloaded
Need 15 amp circuit
Need 15 amp slow-blow fuse
Low voltage
What to Do
Reduce line load by removing
other lights, appliances
Slow down rate of feed
Vacuum sawdust from motor to
allow normal air circulation
Check alignment
Sharpen blade
Slow down rate of feed
Call your electrician
Install correct fuses
Check voltage. Norm'_ loads can
lye,vffely handled at 10% above or
below nameplate voltage; heavy
loads need same voltage at motor
terminal as on nameplate
Motor starts slowly or fails to
come to ful! lx_wer
Incorrect gauge extension cord
Overloaded power line
Undersize wires or circuit too long
Refer to table in Electxical
Connections
Reduce line load by removing
other lights, appliances
Increase wire size or shorten
length of wiring
Motor will not run Protector circuit open
Low voltage
Sawdust build-up
Bent or bound-up arbor shaft
Push re-set button; listen and feel
for click
Check power line for correct volt-
age
Vacuum motor
Check that shaft turns freely by
hand; if it doesn't, contact Sears
Fuses blow when motor is turned
on
Internal damage
Take ,sawto Sears for service
66