Owner`s manual

Bell Wire
I 1
Safety Reversing Sensor
DiagnosticChart
Safetyreversingsensorswire
open(brokenor disconnected).
OR
Safetyreversingsensorswire
shortedor black/whitewire
reversed.
Doorcontrolorwire shorted.
Safetyreversingsensorsslightly
misaligned(dim or flashingLED).
Motoroverheatedor possible
RPMsensorfailure. Unplugto
reset.
Motorcircuitfailure.
Replacereceiver logicboard.
Yourgaragedoor opener is programmed with self-diagnostic capabilities.
The "Learn" button/diagnostic LED will flash a number of times then pause
signifying it has found a potential issue. Consult Diagnostic Chart below.
0 Symptom:One orboth of the Indicatorfightson the safetysensorsdo notglow steady.
Inspect sensorwires for a short (staple in wire), correct wiring polarity (black/white
wires reversed), broken or disconnected wires, replace/attachas needed.
Disconnectall wires from back of motor unit.
Removesensors from brackets and shorten sensor wires to 1-2 ft (30-60 cm) from
back each of sensor.
Reattachsending eyeto motor unit using shortenedwires. If sending eye indicator
light glows steadily, attach the receiving eye.
Align sensors, if the indicator lights glow replacethe wires for the sensors. If the
sensor indicator lights do not light, replacethe safety sensors.
Q Symptom:LEDis not lit ondoorcontrol.
Inspect door control/wires for a short (staple in wire), replace as needed.
Disconnectwires at door control, touch wires together. If motor unit activates,replace
door control.
If motor unit does not activate,disconnect door control wires from motor unit.
Momentarily short across red and white terminals with jumper wire. If motor unit
activates, replacedoor control wires.
Q Symptom:Sendingindicatorlight glowssteadily, receivingindicatorlight is dim or
flashing.
Realignreceiving eye sensor, clean lens and secure brackets.
Verify door track is firmly securedto wall and does not move.
Q Symptom:Motorhas overheated;the motor unit doesnotoperate or trolleyis stuckon
stopbolt = Motorunit humsbriefly;RPM Sensor= Shorttravel 6-8" (15-20 cm).
Unplug unit to reset. Try to operate motor unit, check diagnostic code.
If it is still flashing 5 times and motor unit moves6-8" (15-20 cm), replace
RPMsensor.
If motor unit doesn't operate, motor unit is overheated.Wait 30 minutes and retry. If
motor unit still will not operate replacelogic board.
0 Symptom:Motorunit doesn'toperate.
Replacelogic board becausemotor rarely fails.
34