Installation Step 6
Install the Door Control I
Locate the Door Control within sight of the door
at a minimum height of 5 feet where small
children cannot reach, and away from all moving
parts of the door and door hardware.
The door control is typically attached directly to the
wall. If installinginto drywall,drill5/32" holes and use
the anchors provided.
Stdp 1/4" of insulation from one end of the bell
wire; connect the wire to the two screw terminals
on the back of the Door Control: white to 2, and
white/red to 1.
Fasten the Door Control securely with
6ABx1-1/2" screws.
Run the bell wire up the wall and across the ceiling
to the opener. Use insulated staples to secure the
wire in several places. Be careful not to pieme the
wire with a staple, thereby resulting in a short.
Receiver terminal screws and the antenna are
located on the back panel of the opener. Position
the antenna wire as shown.
Then connect the bell wire to the opener terminal
screws: white to 2 and white/red to 1.
Remember to affix the User Safety instruction
label to the wall near the Door Control, and the
Maintenance Instruction Label in a prominent
location on the inside of the garage door.
f the label adhesive will not adhere to your garage
wall surface (or becomes loose with time), use tacks
to secure the label alongside the Door Control.
Page 29 explains how to operate the opener using
the door control.
Children operating or playing with a garage
door opener can injure themselves or others.
The garage door could close and cause
serious injury or death.
Install the Door Contro! (or any additional pdsh
buttons) out of the reach of children and av/ay
from all moving parts of the door and door
hardware, but where the garage door Is visible.
Do not allow children to operate the ptmh
button or the remote controls.
A moving garage door could injure someone
under it. Activate the opener only when the
door is properly adjusted, you can see it clearly,
and there are no obstructions to door travel.
Do NOT connect the power and operate the
opener at this time. The trolley will travel to the
full open position but will not return to the
close position until the sensor beam is
connected and properly aligned.
See Safety Reversing Sensor Instructions
beginnning on page 19.
I Hardwareih°wn Actual Size _
illlillstrlnlni_tllnUUinl_ll! _
6ABx1-1/2" Screw Insulated
Ocy W=tllAnchors Door Control Burton Staples
j
2-Concluctor
Be!l Wire
I
2-Conductor
Bell Wire
Door Contn_
Terminal Screws I
- I..Jghted
Ooo¢ Control
Burton
Opener
Terminal
Screws
Back Panel
o! Opener
1R