Operating instructions

Page 16
Test Number 9--Ohms Test
1. The ohmmeter test is powered by an internal 9 volt battery. No
zero calibration is required by the operator. Place Function
Selector Switch in the Ohms position and select either the Hi
or Lo range to match the component under test. (X i or X lOOd)
2. CONNECTIONS: Insert the white Plug Ohms Lead into the corresponding
tester socket as illustrated below.
3. OPERATION: The meter will read full scale at INF. with cllps,open,
and when the clips are connected together will read zero on the
left. (See Paragraph #6.) To measure resistance, connect the clips
to the component to be tested and read the prope_ Ohms scale. (X 1 or
x 1ooo)
4. IMPORTANT CAUTION: ALWAYS disconnect ALL LĀ£ADS from any electrical
part to be tested on the vehicle. Failure to observe this caution may
result in damage to the tester.
5. Refer to manufacturer's specifications for normalresistance value
of any part being tested, ignition cables, ballast resistor, coil
windings, etc.
WHITE PLUG
FIGURE 19
OHMMETERCONNECTIONS
RED
OHMMETER BATTERY
The 9 volt battery ts located in the rear com-
partment,
Observe correctt polarity when installing
battery.
IMPORTANT: 9 VOLT BATTERY ( SEARS#
64i7) IS NOT SUPPLIED WiTH THIS ANA-
LYZER.--OHMS CIRCUIT WILL NOT WORK
WITHOUT BATTERY.
I i
SECONDARY
OHMS
OHMS TESTS ON VARIOL
VEHICLE COMPONENTS
PRIMARY
OHMS
1
FUSE
BLACK
BA LLAST RESISTOR
COIL