CUSTOMER RESPONSIBILITIES
DRAINING GEAR HOUSING LUBRICANT
With motor upright, remove the vent screw and the fill
and drain screw. Allow lubricant to drain completely
(Figure 32).
IMPORTANT: WHEN ADDING OR CHANGING LUB-
RICANT, INSPECT FOR WATER CONTAMINATION.
TO INSPECT, LOOSEN (DO NOT REMOVE) GEAR
HOUSING DRAIN PLUG SCREW AND ALLOW A
SMALL AMOUNT OF LUBRICANT TO DRAIN. IF
WATER-IS PRESENT IT WILL DRAIN PRIOR TO THE
ACTUAL LUBRICANT. SHOULD WATER BE PRES-
ENT, TAKE YOUR ENGINE TO YOUR SEARS SERVICE
CENTER.
VENT SCREW
FILL AND DRAIN SCREW
FIGURE 32
ADDING/REFILLING LUBRICANT
Remove fill and drain screw and washer, an insert
nozzle of tube into hole (Figure 33).
Remove vent screw and washer (Figure 34).
Add lube until it appears at vent hole (Figure 35).
Reinstall vent screw and washer, and tighten securely.
Remove nozzle, reinstall filland drain screw and wash-
er, and tighten securely.
Remove vent screw and allow motorto stand uprightfor
at least one-half (1/2) hour.
Recheck lube level. Add lube ifnecessary to bring level
up totop hole.
Reinstall vent screw and washer. Tighten securely.
_]==0
FILL AND DRAIN SCREW
FIGURE 33
VENT SCREW
FIGURE 34
FIGURE 35