Owner`s manual

EMPTYING LIQUID WASTE
FROM THE TANK
Your Craftsman Wet'Dry Vacuum can be emptied of liquid
waste by removing the drain cap. To empty, turn unit off
and remove plug from wall receptacle. Remove the drain
cap, located on front of vacuum at bottom of tank, and
deposit the liquid waste contents into a suitable drain. After
the tank is empty, return the drain cap to its original posi-
tion. To continue use, plug the cord into the wall receptacle
and turn unit on. Model No. 17920 does not have a drain
cap. To empty, remove lid, and pour water out into a suit-
able drain.
AUTOMATIC SHUT-OFF
The vacuum is equipped with an automatic suction shut-off
that operates when picking up liquids. As the level of the
liquid rises in the tank, an internal float rises until it seats
itself against a seal at the intake of the motor, shutting off
suction. When this happens, the motor will develop a high-
er than normal pitch noise and the suction is drastically
reduced. If this occurs, turn unit off immediately. Failure to
turn unit off after float rises and shuts off suction will result
in extensive damage to the motor. To continue use, empty
the liquid waste from the tank as outlined in the previous
paragraph.
NOTE: If accidentally tipped over, the vacuum could lose
suction. If this occurs, place vac in upright position and
turn switch off. This will allow the float to return to its nor-
mal position, and you will be able to continue operation.
BLOWER FEATURE
This vacuum can be used as a powerful blower. To use
your unit as a blower unscrew blower port cover located on
the backside of the motor housing (Figure 16). The blower
port cover is equipped with a retaining strap to prevent loss
of the port cover while blower is in use. Insert hose end
with locking-nut into blower port of tank and tighten. Be
cautious when using as a blower due to the powerful force
of air.
_1= WARNING: Always wear eye protection to pre-
vent rocks or debris from being blown or ricochet-
ing into the eyes or face which can result in seri-
ous injury.
ATTACHING SQUEEGEE TO
14" FLOOR NOZZLE
Align one side of squeegee with brush
side of nozzle. Push them together,
starting at one end and working toward
the other. Repeat process to attach
other side of squeegee to front side of
nozzle(Figure 17).
i
STORAGE
Before storing your vacuum cleaner thetank should be emp-
tied and cleaned. The power cord can be wrapped around the
cord wraps provided on the rear of the tank(Rgure 18). A
hose holder has been provided for easy storage of the hose.
Install hose holder end with fastener onto hose. Slide or snap
fastener into notch, securing it in place. Remove extension
wands and/or accessory from end of hose and place hose
end into open end of hose holder to secure hose in place for
easy storage (Figure 19).
SYMPTOM POSSIBLECAUSE(S) CORRECTIVEACTION
1.Packedin thetank 1.Checkin tankParts/accessories
are missing
Dustdischarging
Fromtheexhaust
Lossof suction/
performance
Water misting out
exhausted air
Static shock
1. Filter not installed/
not installed properly
2. Filter is damaged
3. Filter is clogged
or dust is too fine
4, Filter is not functional
1. Loose hose
connection.
_2. Lid/motor air leak
3. Drain air leak
(not all models)
4,Filter clogged
5. Full tank
6. Hole in hose
7. Obstruction in
hose or nozzle
1. Saturatedormissing
foamsleeve
2. Inletdeflectorshield
isnet installedproperly
1. Dry' environment
2. Relative humidity of
air is low
1. Properlyinstall
the filter
2. Replace the filter
3. Use a mere efficient filter
4. Clean or replace
the filter
1. Tighten hose connection
2. Check lid latches
3. Tighten drain cap
4. Clean or replace filter
5. Empty tank
6. Replace hose
7. Remove obstruction
if present
t. Check that foam sleeve
is in place or replace
with a clean dry tilter
2. Check to make sure
the inlet deflector is
installedproperly. Facing
up for wet pick-up.
Facing down for dry
pick-up.
1. Add moisture to air (if
practical use a console
or installed humid tier,)
2. This situation is
temporary and does not
affect the use of the
vacuumcleaner,