Owner`s manual

TROUBLESHOOTING CHART
SYMPTOM CORRECTIVE ACTION
Leaks at the metal
clamps
Release all pressure
in system before
working on clamp!
POSSIBLE CAUSE(S)
1. Loose clamps or O_Ring
not sealed
1. First check the clamp tightening screw to see flit is tight. If it is tight and
slight leakage still occurs, place a piece of wood on the clamp and
firmly tap the wood with a hammer. Repeat tl_s operation around
the edge of the clamp and retighten the clamp screw. If leak continues,
disassemble clamp and pump halves and check to see _at O-Ring is
properly seated and no foreign material is on O-Ring or O seat.
Reassemble pump.
Type of
System
Shallow
Well
2" Single
Pipe
3" Single
Pipe
4" Double
Pipe
Jet Pkg.
Stock No.
29650
2967"t
29902"*t
29660***
Pump
Model No.
390.2511
390.2511
390.2511
390.2511
Pump Performance
at 40 PSI Discharge Pressure
HP
1/2
1/2
1/2
1/2
5
8.2
(In Gallons Per Hinute)
Pumping Depth in Feet
10 15 20 30
7.3 6.2 5.0
3.4
4.1
4.1
40 50
2.8 2.3
3.2 2.0
3.2 2,0
60 70
1.8 1.3
1.2
1.2
Use 160 PSI Min. Rating Plastic Pipe.
* Jet Package No. 2967 - 2" Single Pipe (use 1-1/4" galvanized pipe).
** Jet Package No. 29902 - 3" Single Pipe (use 1-1/4" galvanized pipe).
*** Jet Package No. 29660- 4" Double Pipe.
t Must be ordered through Sears Product Service, 1-800-366-7278.
8O
9O
15