Operating instructions

AFTEREACHUSE
Water should not remain in the unit for long periods of time.
Sediments or minerals can deposit on pump parts and
"freeze" pump action. Followthese procedures after every
use:
1. Shut off engine, turn off water supply, point gun in a
safe direction, press red button and squeezetrigger to
relieve trapped pressure, and let enginecool.
WARNING
Thehighpressurestreamofwaterthatthis
equipment produces can cut through skin and its
,_ underlying tissues, leading to serious injury and
possible amputation.
Spray gun traps high water pressure, even when
engine is stopped and water is disconnected,
which can cause injury.
. Keephighpressurehoseconnectedto pumpandspraygun
whilesystemis pressurized.
ALWAYSpointspraygunin safedirection,pressredbutton
andsqueezesprayguntrigger,to releasehighpressure,every
time youstopengine.
2. Disconnect hose from spray gun and high pressure
outlet on pump. Drain water from hose, gun, and spray
tip extension. Usea ragto wipe off the hose.
3. Empty pump of all pumped liquids by pulling recoil
handle about 6 times. This should remove most liquid in
pump.
4. Coil high pressure hose and properly hang it on hook
provided on accessorytray.
5. Store unit in a clean, dry area.
6. If storing for more than 30 dayssee Long Term Storage
on next page.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severeburns or
death.
WHEN STORINGFUELOR EQUIPMENTWITHFUELINTANK
Storeawayfromfurnaces,stoves,waterheaters,clothes
dryers,or otherappliancesthathavepilot light or otherignition
sourcebecausetheycanignitefuelvapors.
22