Owner`s manual

7
SPECIFICATIONS
Function Range Resolution
Accuracy
4nF 1pF ±(5.0% reading + 10 digits)
40nF 10pF ±(5.0% reading + 7 digits)
400nF 0.1nF
4!F 1nF
40µF 10nF
±(3.5% reading + 5 digits)
Capacitance
200µF 0.1µF ±(5.0% reading + 5 digits)
Duty Cycle 0.1-99.9% 0.1% ±(1.2% reading + 2 digits)
Pulse width: 100µs - 100ms
9.999Hz 0.001Hz
99.99Hz 0.01Hz
±(1.5% reading + 5 digits)
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
999.9kHz 100Hz
±(1.2% reading + 2 digits)
Frequency
9.999MHz 1kHz ±(1.5% reading + 4 digits)
Temp °F -4 to 1400°F 1°F
Temp °C -20 to 760°C 1°C
±(3.0% reading + 3 digits)
NOTE: Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than
70% RH.