Product specifications

Drainthefueltank,
Starttheengineandletitrununtilthe
fuel lines and carburetor are empty.
NeveLuse engine or carburetor cleaner
producLsint-he fuel tank or permanent
damage may occur.
Use fresh fuel next season.
IOTE: Fuel stabilizer is an acceptable
Lltemative in minimizing the formation of
_el gum deposits during storage. Add sta-
,ilizer to gasoline in fuel tank or storage
:ontainer. Always follow the mix ratio
ound on stabilizer container. Run engine
it least 10 minutes after adding stabilizer
o allow the stabilizer to reach the carbure-
or. Do not drain the gas tank and carbure-
or if using fuel stabilizer.
"NGINE OIL
)rain oil (with engine warm) and replace
_ith clean engineoil. (See "ENGINE" in
he Maintenance section of this manual).
:YLINDER(S)
Remove spark plug(s).
Pour one ounce of oil through spark plug
hole(s) into cylinder(s).
Tum ignition key to "START" position for
a few seconds to distn'bute oil.
Replace with new spark plug(s).
OTHER
Do not store gasoline from one season
to another.
Replace your gasoline can if it starts to
rust. Rust and/or dirt in your gasoline will
cause problems.
If possible, store your tractor ind_rs
and cover if to give protection from dust
and dirt.
Cover your tractor with a suitable protec-
tive cover that does not retain moisture.
Do not use plastic. Plastic cannot
breathe, which allows condensation to
form and cause your tractor to rust.
IMPORTANT: Never cover tractor while
engine and exhaust areas are still warm.
29