Manual
Air Compressor Pump (not shown);
Compresses air into the air tank.
Working air Je not avaiJable until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
comDressor is operating, the cheek
valve is "open", allowing compressed
air to enter the sir tank When the air
compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure re remain inside
the sir tank.
How to Use Your Unit
How to Stop:
1. Set the On/Auto/Off ]ever to
"OFF".
Before First Start-up
Break-in Procedure
Serious damage
may result if the
following break-in instructions are
not closely followed,
Thisprocedure is required before the
air compressor Is put into service and
when the check valve or a complete
compressor pump has been
replaced
1 Make sure the On/Aut0!Off lever
is in the "OFF" position.
NOTE: Pull coupler back untiP it c_icks
to prevent air from escaping through
the quick connect.
On/Au[o/
Off Leve
2,
Plug the power cord into the
correct branch cimuit receptacle.
(Refer to Voltage and Circuit
Protectlon paragraph inthe
Installation section of this
manual.)
3,
Open file drann v_lvo iully
(counterclockwise) to permit air
toescape and prevent air
pressure build up in the air tank
during the break-in period.
4. Move the OnlALrto/Ofl lever to
"ONIAUTO" posi[iorl The
compressor will start.
5,
Run the compressor for 15
minutes. Make sure the drain
valve is open a,nd there is
minima] air pressure build-up in
tank,
6,
After 15 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop,
The compressor is now ready for use.
13-ENQ D28336