Manual

PROBLEM
Pressure reading
on the regulated
pressure gauge
drops when an
accessory is
used.
Compressor is
not supplying
enough air to
operate
accessories.
CAUSE
It is normal for "some"
3ressure drop to occur.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Hole in hose.
Check valve restricted.
CORRECTION
If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions in the
"Description of Operation"
paragraph in the "Operation
Section.
NOTE: Adjust the regulated
)ressure under flow
conditions (while accessory
is being used).
Decrease amount of air
usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Remove and clean, or
replace.
Air leaks. Tighten fittings.
Regulator knob Damaged regulator. Replace.
has continuous
air leak.
Regulator will Damaged regulator. Replace.
not shut off air
outlet.
D29408 20_ ENG