How to Guide
Table Of Contents
- English (United States)
- Français (Canada)
- INTRODUCTION
- INSTALLATION
- RÉGLAGE
- BATTERIE DE SECOURS Modèle CMXEOCG982
- COMMANDE myQ® PAR TÉLÉPHONE INTELLIGENT
- FONCTIONNEMENT
- Caractéristiques
- Tableau de commande à double fonction Modèle CMXEOCG572
- Commande de porte Modèle CMXEOCG322
- Tableau de commande de détection de mouvement Modèles CMXEOCG772 et CMXEOCG982
- Télécommande et clavier sans fil
- Pour effacer la mémoire
- Ouverture manuelle de la porte
- La pile de la télécommande
- Soin de votre actionneur de porte
- DÉPANNAGE
- PIÈCES DE RÉPARATION
- ACCESSOIRES
- GARANTIE
- GUIDE DE SÉCURITÉ ET D’ENTRETIEN DE L’OUVRE-PORTE DE GARAGE AUTOMATIQUE
- Español (México)
- INTRODUCCIÓN
- INSTALACIÓN
- AJUSTES
- BATERÍA DE RESPALDO Modelo CMXEOCG982
- CONTROL myQ® PARA TELÉFONOS INTELIGENTES
- FUNCIONAMIENTO
- Características
- Panel de control de doble función modelo CMXEOCG572
- Control de la puerta Modelo CMXEOCG322
- Panel de control de detección de movimiento Para los modelos CMXEOCG772 y CMX...
- Control remoto y teclado inalámbrico
- Para borrar la memoria
- Para abrir la puerta manualmente
- La batería del control remoto
- Mantenimiento de su abre-puertas de garaje
- RESOLUCIÓN DE PROBLEMAS
- Piezas de repuesto
- ACCESORIOS
- GARANTÍA
- GUÍA DE SEGURIDAD Y MANTENIMIENTO DEL ABRE-PUERTAS DE GARAJE AUTOMÁTICO
ADJUSTMENT STEP 2
TEST THE SAFETY REVERSAL SYSTEM
TEST
1. With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid
flat) on the floor, centered under the garage door.
2. Press the remote control or wall-mounted door control to close the door.
The door should stop and reverses when it makes contact with the board.
The door returns to the previous open position. Opener beeps and lights
flash 5 times.
3. If the door reverses, remove the board. The test is complete.
If the door stops but does not reverse:
1. Review the installation instructions provided to insure all steps were
followed;
2. Refer to Adjustment Step 1 and and set the down limit closer to the garage
floor. NOTE: On a sectional door, make sure adjustments do not force the
door arm beyond a straight up and down position.
3. Repeat the Safety Reversal test.
If the test continues to fail, call a trained door systems technician.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
• Each adjustment of door arm length, limits, or force controls.
• Any repair to or adjustment of the garage door (including springs and
hardware).
• Any repair to or buckling of the garage floor.
• Any repair to or adjustment of the opener.
Without a properly installed safety reversal system, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• After ANY adjustments are made, the safety reversal system MUST be tested.
Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid
flat) on the floor.
1-1/2" (3.8 cm) board
(or a 2x4 laid flat)
ADJUSTMENT STEP 3
TEST THE SAFETY REVERSING SENSORS
1. Press the remote control push button to open the door.
2. Place the opener carton in the path of the door.
3. Press the remote control push button to close the door. The door will not
move more than an inch (2.5cm), and the opener lights will flash.
The garage door opener will not close from a remote control if the LED in either
safety reversing sensor is off (alerting you to the fact that the sensor is misaligned
or obstructed). If the garage door opener closes the door when the safety reversing
sensor is obstructed (and the sensors are no more than 6" (15cm) above the floor),
call for a trained door systems technician.
Without a properly installed safety reversing sensor, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
Safety Reversing Sensor
Safety Reversing Sensor