Owner’s Manual Permanently Lubricated Tank Mounted AIR COMPRESSOR Model No. 919.152163 • • • • • • • Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman N090754 Rev.
TABLE OF CONTENTS WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPECIFICATION CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SAFETY GUIDELINES - DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . 3-8 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPECIFICATION CHART Model No. Running HP Bore Stroke Voltage/Hz-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psig SCFM @ 90 psig Regulated Pressure Rating (Approximate) Quick Connect Type 919.152163 0.8* 1.875" (47.6 mm) 1.250" (31.8 mm) 120/60 15 amps Time Delay 6 Gallon (22.7 liters) 120 psig 150 psig 3.7 * 2.6 * 3–150 psi 1/4" (6.4 mm) Industrial *Tested per ISO 1217 Refer to Glossary for abbreviations.
HAZARD • • RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN HOW TO PREVENT IT It is normal for electrical contacts • Always operate the compressor in a within the motor and pressure well ventilated area free of combusswitch to spark. tible materials, gasoline, or solvent vapors. If electrical sparks from compressor • come into contact with flammable vapors, they may ignite, causing fire or explosion.
• Exposure to chemicals in dust cre- • Work in an area with good cross ventilation. Read and follow the ated by power sanding, sawing, safety instructions provided on the grinding, drilling, and other conlabel or safety data sheets for the struction activities may be harmful. materials you are spraying.
Attachments & accessories: • Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflatables can cause them to explode or fly apart, and could result in serious injury. • Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
HAZARD • RISK FROM FLYING OBJECTS WHAT CAN HAPPEN HOW TO PREVENT IT • Always wear certified safety equipThe compressed air stream can ment: ANSI Z87.1 eye protection cause soft tissue damage to (CAN/CSA Z94.3) with side shields exposed skin and can propel dirt, when using the compressor. chips, loose particles, and small objects at high speed, resulting in • Never point any nozzle or sprayer property damage or personal injury. toward any part of the body or at other people or animals.
HAZARD • RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air com• Review and understand all instrucpressor could lead to serious injury tions and warnings in this manual. or death to you or others. • Become familiar with the operation and controls of the air compressor. • Keep operating area clear of all persons, pets, and obstacles. • Keep children away from the air compressor at all times.
GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL®, CUL, CULUS, ETL®, CETL, CETLUS, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Standards for Safety.
ASSEMBLY Unpacking Remove unit from carton and discard all packaging. INSTALLATION HOW TO SET UP YOUR UNIT 2. Location of the Air Compressor • • • Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling.
Extension Cords Voltage and Circuit Protection If an extension cord must be used, be sure it is: Refer to the specification chart for the voltage and minimum branch circuit requirements. Risk of Overheating. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. • • • • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product in good condition no longer than 50 feet 14 gauge (AWG) or larger.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge Outlet Pressure Gauge On(I)/Off(O) Switch Safety Valve Quick Connect Regulator Description of Operation Become familiar with these controls before operating the unit.
Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank. Check Valve Motor Overload Protector (not shown): The motor has a thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart: 1.
MAINTENANCE Customer Responsibilities Before Daily each use or after each use X X Check Safety Valve Drain Tank Remove tank from service 1 - For more information, Contact a Trained Service Technician. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
SERVICE AND ADJUSTMENTS ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. To Replace Regulator Manifold 1. 2. 3. Release all air pressure from air tank.
weaken the air tank causing a risk of STORAGE air tank rupture. Before you store the air compressor, make sure you do the following: 1. Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary. 2. Drain water from air tank. See To Drain Tank under Maintenance. Water will condense in the air tank. If not drained, water will corrode and 3. 4. 16 - ENG Protect the electrical cord and air hose from damage (such as being stepped on or run over).
TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. PROBLEM CAUSE CORRECTION Excessive tank pressure - safety valve pops off. Pressure switch does not shut off motor when compressor reaches "cut-out" pressure.
PROBLEM CAUSE CORRECTION Pressure reading on the regulated pressure gauge drops when an accessory is used. It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Compressor is not supplying enough air to operate accessories.
PROBLEM Motor will not run. CAUSE Fuse blown, circuit breaker tripped. CORRECTION Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay fuse. Check for low voltage problem. Check the extension cord. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit.
AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919.152163 PARTS SHOWN FOR REFERENCE ONLY N090754 Air Compressor - MODEL NUMBER 919.
PARTS LIST Air Compressor Model Number 919.152163 ITEM PART NO. NO. DESCRIPTION 2 I3 4 5 7 8 9 9 10 11 18 19 24 28 31 32 33 34 35 36 856 856 856 Isolator Kit (Incl. 3) Screw Screw Nipple Drain Valve Safety Valve Manifold (Incl.
PUMP DIAGRAM Air Compressor Model Number 919.
PARTS LIST Air Compressor Model Number 919.152163 ITEM PART NO. NO.
CONTENIDO GARANTÍA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 CUADRO DE ESPECIFICACIONES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 DEFINICIONES DE NORMAS DE SEGURIDAD . . . . . . . . . . . . . . . . . . . . . . . . . . 25 IMPORTANTES INSTRUCCIONES DE SEGURIDAD . . . . . . . . . . . . . . . . . . . . 25-30 GLOSARIO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CUADRO DE ESPECIFICACIONES Modelo Nº Potencia de trabajo Diámetro interior Carrera Voltaje-corriente manofásica Circuito mínimo requerido Tipo de fusible Capacidad de aire en el tanque Presión de corte de entrada Presión de corte de salida SCFM a 40 psig SCFM a 90 psig Clasificación de presión regulada (aproximadamente) Tipo de conexión rápida 919.
PELIGRO RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • Es normal que los contactos eléctricos • dentro del motor y el interruptor de presión produzcan chispas. Opere siempre el compresor en un área bien ventilada libre de materiales combustibles, gasolina o vapores de solventes. • Si las chispas eléctricas del compresor • entran en contacto con vapores inflamables, pueden encenderse, provocando un incendio o una explosión.
• La exposición a productos químicos en el polvo producido por las herramientas eléctricas al lijar, aserrar, esmerilar, taladrar y otras actividades de la construcción puede ser peligrosa. • Los materiales pulverizados como pintura, solventes para pinturas, removedor de pintura, insecticidas y herbicidas pueden contener vapores dañinos y venenos. • Trabaje en un área con buena ventilación cruzada.
Neumáticos: • El inflado excesivo de los neumáticos podría causar lesiones graves y daño a la propiedad. • Utilice un medidor de presión de neumáticos para controlar la presión de éstos antes de cada uso y mientras los infla; observe el flanco para ver la presión correcta del neumático. NOTA: Los tanques de aire, los compresores y el equipo similar que se usa para inflar neumáticos pueden llenar neumáticos pequeños como éstos con mucha rapidez.
PELIGRO RIESGO DE OBJETOS DESPEDIDOS ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • La corriente de aire comprimido • puede provocar lesiones en los tejidos blandos de la piel expuesta y puede impulsar suciedad, astillas, partículas sueltas y objetos pequeños a gran • velocidad, que pueden producir daños en la propiedad y lesiones personales. • Utilice siempre equipo de seguridad certificado: anteojos de seguridad ANSI Z87.1(CAN/CSA Z94.3) con protección lateral al usar el compresor.
PELIGRO RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE SUCEDER? • CÓMO EVITARLO La operación insegura de su compresor de aire podría producir lesiones graves o la muerte, a usted mismo o a otras personas. • • • • • • • • Revise y comprenda todas las instrucciones y advertencias de este manual. Familiarícese con la operación y los controles del compresor de aire. Mantenga el área de operaciones libre de personas, mascotas y obstáculos. Mantenga a los niños alejados del compresor de aire en todo momento.
GLOSARIO Familiarícese con los siguientes términos, antes de operar la unidad: CFM: (Cubic feet per minute) Pies cúbicos por minuto. SCFM: (Stardard cubic feet per minute) Pies cúbicos estándar por minuto; una unidad de medida que permite medir la cantidad de entrega de aire. PSIG: (Pound per square inch) Libras por pulgada cuadrada.
ENSAMBLAJE Desempaque Extraiga la unidad de su caja y descarte todas las partes de embalaje. INSTALACIÓN 2. CÓMO PREPARAR LA UNIDAD Ubicación del compresor de aire • • • Ubicar el compresor de aire en un lugar limpio, seco y bien ventilado. El compresor de aire debe colocarse alejado por lo menos 30,5 cm (12 pulg) . de las paredes o de cualquier otra obstrucción que interfiera con el flujo de aire. La bomba del compresor de aire y su casco han sido diseñados para permitir un enfriamiento adecuado.
Cables de extensión eléctrica Protección del voltaje y del circuito Si - no obstante - debe utilizarse una extensión de cable, asegúrese de que: • La extensión eléctrica de 3 conductores, tenga un enchufe de conexión a tierra de 3 hojas, y que exista un receptáculo que acepte el enchufe del producto. • Esté en buenas condiciones. • No más largo que 15,2 m (50 pies). • Sea calibre 14 (AWG) o mayor. (La capacidad de los cables se incrementa a medida que su número ordinal decrece.
OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
3. Gire la perilla del regulador contra el sentido del reloj para regular la presión de la salida a cero. 4. Conecte la manguera y accesorios. Riesgo de operación insegura. Sostenga la manguera firmemente con las manos al instalarla o desconectarla para evitar la desconexión repentina de la manguera. Válvula de retención: Cuando el compresor de aire se encuentra funcionando, la válvula de retención está "abierta", permitiendo la entrada del aire comprimido al tanque de aire.
MANTENIMIENTO Responsabilidades del cliente Antes de cada uso Verifique la válvula de seguridad Diariamente o luego de cada uso Remítase a la etiqueta de advertencia del tanque X Drenaje del tanque X X1 El tanque debe ser dado de baja 1 - Para mayor información,Contacte a un técnico de servicio calificado La unidad arranca automáticamente cuando está conectada.
Riesgo de daño a la propiedad. Drene el agua del tanque de aire puede contener aceite y óxido, lo que puede provocar manchas. 6. Una vez drenada el agua, cierre la válvula de drenaje. Ahora puede guardar el compresor de aire. NOTA: Si la válvula de drenaje estuviese obstruida, elimine toda la presión de aire. Luego puede sacarla, limpiarla y reinstalarla. SERVICIO Y AJUSTES TODO TIPO DE MANTENIMIENTO Y REPARACIONES NO MENCIONADOS EN ESTE MANUAL, DEBERÁN SER EFECTUADOS POR PERSONAL TÉCNICO ESPECIALIZADO.
ALMACENAJE 3. Antes de guardar su compresor de aire, asegúrese de hacer lo siguiente: 1. Revise la sección Mantenimiento de las páginas precedentes y ejecute el mantenimiento programado de acuerdo a la necesidad. 2. Drene el agua contenida en el tanque de aire. Consulte el punto Cómo drenar el tanque en la sección Mantenimiento. 4. Riesgo de Explosión. El agua se condensa dentro del tanque de aire.
GUÍA DE DIAGNÓSTICO DE PROBLEMAS Riesgo de Operación Insegura. La unidad arranca automáticamente cuando está enchufada. Al hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor del tomacorriente, drenar la presión de aire del tanque y esperar a que el compresor se enfríe. PROBLEMA CAUSA CORRECCIÓN Presión excesiva del tanque - la válvula de seguridad se dispara.
PROBLEMA CAUSA CORRECCIÓN La lectura de la presión sobre un manómetro desciende cuando se utiliza un accesorio. Es normal que ocurra algún descenso en la presión. Si hubiese una caída excesiva de presión durante el uso del accesorio, ajuste el regulador de acuerdo a las instrucciones de la Descripción de operaciones en la sección Operación. NOTA: Ajuste la presión regulada bajo condiciones de flujo (mientras se esté usando el accesorio).
PROBLEMA El motor no funciona. CAUSA CORRECCIÓN Fusible fundido; interruptor automático del circuito disparado. Verifique la caja de fusibles observando la existencia de fusibles fundidos y sustitúyalos en caso de necesidad. Restablezca el interruptor automático. No use un fusible o interruptorautomático con valores que excedan los especificados para la rama de su circuito. Verifique el uso del fusible adecuado. Debe usarse un fusible de acción retardada.
NOTES / NOTA 42
Repair Protection Agreements Congratulations on making a smart purchase. Your new Craftsman® product is designed and manufactured for years of dependable operation. But like all products, it may require repair from time to time. That’s when having a Repair Protection Agreement can save you money and aggravation.