Isopropanol bulk
Safety Data Sheet
Product code: 402_bulk
Print date: 17.01.2017 Page 3 of 7
ITW LLC & Co. KG
according to Regulation (EC) No 1907/2006
Use water spray jet to protect personnel and to cool endangered containers. Suppress gases/vapours/mists
with water spray jet. Contaminated fire-fighting water must be collected separately. Do not allow to enter into
surface water or drains.
Additional information
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Take precautionary measures against static discharge. Remove all sources of ignition. Provide adequate
ventilation. Wear a self-contained breathing apparatus and chemical protective clothing.
Stop and contain spill/release if it can be done safely. If this cannot be done, allow fire to burn under control. Do
not allow to enter into surface water or drains. Explosion hazard.
6.2. Environmental precautions
Ventilate affected area.
6.3. Methods and material for containment and cleaning up
SECTION 7: Handling and storage
7.1. Precautions for safe handling
If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe
gas/fumes/vapour/spray.
Advice on safe handling
Keep away from sources of ignition. - No smoking. Take precautionary measures against static discharges.
Advice on protection against fire and explosion
7.2. Conditions for safe storage, including any incompatibilities
Keep container tightly closed. Keep in a cool, well-ventilated place. Protect against direct sunlight. Keep away
from sources of ignition. - No smoking.
Requirements for storage rooms and vessels
Do not store together with: Material, rich in oxygen, oxidizing.
Advice on storage compatibility
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Exposure limits (EH40)
Categoryfibres/mlmg/m³ppmSubstanceCAS No Origin
TWA (8 h)400Propan-2-ol67-63-0 999 WEL
STEL (15 min)500 1250 WEL
8.2. Exposure controls
If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe
gas/fumes/vapour/spray.
Appropriate engineering controls
Remove contaminated, saturated clothing immediately. Protect skin by using skin protective cream. After work,
wash hands and face. When using do not eat or drink.
Protective and hygiene measures
Revision No: 1,06 Revision date: 27.05.2015 GB - EN