Manual

PAGE 15
SPECIFICATIONS
Compressor
Attack Time: FAST; measured by doing 18 dB of Gain Reduction. The time to 18 dB of
Gain Reduction is less than 1mS. 12 dB of the 18 are reached in .4mS.
SLOW; for 6 dB of GainReduction, 100mS
Compressor
Release Time: FAST; From 12 dB of Gain Reduction to No Gain Reduction. 11 of 12 dB
are reached in 50mS (Non Program Dependant Release)
SLOW; 20 sec for a full 12 dB release with PDR enabled.
Limiter
Attack Time: less than 1uS.
Limiter
Release Time: 60mS for 6 dB of Gain Reduction.
Maximum
Signal Level: Input or Output, +25 dBm
Noise Floor: -88 dBm measured 20Hz to 20kHz
Frequency
Response: 5Hz to 55kHz (Hara Mode)
Limiter Slope: Greater than 10 to 1
()
LINE VOLTAGE RANGE
Setting Min. Voltage Max. Voltage
100V 91V 112V
120V 104V 130V
230V
same as 190V 236V
220V
240V 206V 257V