Owner's manual

STEREO LINK
When stereo linked the unit selected as the control master will control all functions on the second
channel. The LCD display will show which unit is the control master. When working in stereo all
controls on the slave unit are disabled.
When switched out / bypassed, Titan is hard bypassed by a relay; this relay will also bypass the unit
when power is off.
LINK-IN-BYPASS For the Link - In - Out switch to work correctly in the link mode the unit that is to be
the slave unit should be set to out. With this setting the Link - In - Out switch will work as a master in -
out switch by moving the switch from LINK to OUT on the master unit.
The link function works by sending data commands from the master unit to the slave unit, being the
side chain is a dsp the side chain functions will precisely match. The analog outputs of the detector
circuits are also tied together during link so that each channel sees the same analog control signals.
Power up during link In normal operation everything is fine as long as both units are powered at the
same time. On power up the master unit will see that it is to be the master and will not start
commutation with the slave for a few seconds longer, allowing the slave unit to be powered up first. If
the master unit is very late on power up or both units have master selected, commutation will fail and
the link will not work. To correct this, switch both units to out and then set the master unit to master.
METER SWITCH
The meter switch selects weather the meter in showing gain reduction or level
0VU = +4dbu with +24dbu being the top of the meter