Use and Care Manual
7
REPLACING THE GERMICIDAL UV LIGHT
WARNING
Always make sure the purifier is turned OFF and UNPLUGGED from power outlet
before replacing UV light.
Always use caution when handling the UV light to prevent accidental breaking of
the bulb.
NEVER touch the glass part of the light. Oil from fingers will reduce the germicidal
performance of the UV light. ALWAYS use gloves, or handle the light only by the
metal area on the ends.
DO NOT use a vacuum to pick up broken bulb glass or handle broken bulb with your
hands. Sweep debris into a plastic bag and dispose properly. Contact your local waste
management authority for instruction regarding recycling and the proper disposal of the
old light(s).
The UV bulb is designed to provide approximately one-year continuous operation. After
one year, the UV Light’s effectiveness is greatly reduced. For maximum protection,
Crane recommends replacing after a year or if the blue UV light does not illuminate
when the UV switch is ON.
MAINTENANCE
CAUTION: Always be sure the purifier is unplugged and switched off before cleaning,
removing filters or attempting to store the item. NEVER PLUG OR UNPLUG THE PURIFIER
WITH WET HANDS.
CLEANING THE WASHABLE PARTICLE FILTER
1. Remove the foam particle filter by pulling out of the unit gently
2. Rinse the particle filter by hand using only warm water
DO NOT place in the dishwasher
DO NOT use hard solvents or detergents
3. Particle filter MUST be thoroughly dry before replacing into the air purifier
CLEANING THE AIR PURIFIER
1. Once unplugged, the exterior of the unit can be wiped clean lightly with a damp
cloth.
DO NOT allow water to get into the intake and outlet grills
DO NOT use gasoline, polish or any chemical solution to clean the air purifier
2. The intake grill and outlet grill can be cleaned of dust with a small brush
3. If you wish to lightly clean the inside of the purifier, please remove filters and
ONLY use a dry, soft cloth to lightly wipe down.
STORING YOUR PURIFIER
Store the purifier is a dry location. Do not place heavy items on top of the purifier during
storage as this may result in possible damage of the appliance. Store the cord in a
clean, dry location away from metal objects. Always check the plug before use to
assure metal items have not become attached.