Drop Humidifiers 1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER FOR THE FOLLOWING MODELS: EE-5301 EE-5301P EE-5301G EE-5301O EE-5301W EE-5301B EE-5301GR If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care. Toll Free: 888-599-0992 Email: customer-service@crane-usa.com PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE.
TABLE OF CONTENTS Table of Contents, Humidifier Models P. 1 Safety Instructions P. 2-3 List of Main Parts P. 4 Technical Specifications P. 5 Operation and Use P. 5-7 Maintenance & Storing Your Humidifier P. 7 Trouble Shooting P. 8 Customer Care P. 9 Warranty P.
IMPORTANT SAFETY INSTRUCTIONS Thank you for purchasing a CRANE Ultrasonic Humidifier. Each unit has been manufactured to ensure safety and reliability. Before using for the first time, please read the instructions carefully and keep them for further reference. WARNING! READ AND SAVE THESE INSTRUCTIONS. Failure to follow all of the instructions listed below may result in electric shock, fire and/or serious personal injury. 1. DO NOT carry Water Tank by handle when it is filled with water.
SAVE THESE INSTRUCTIONS! GENERAL SAFETY INSTRUCTIONS WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire or serious personal injury. The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the user that common sense and caution are a factor which cannot be built into this product, but must be supplied by the user.
THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.
LIST OF MAIN PARTS Fig. 1 (Humidifier Base) 1. Control Knob 2. Water Basin 3. Power Indicator Light NOTE: Depending on humidifier color, the control knob may be a different style Fig. 2 (Top of Water Tank) 4. Mist Outlet Channel 5. Water Tank Handle Fig. 3 (Water Basin) 3. Power Indicator Light 6. Nebulizer 7. Mist Chamber 8. Fan Vent 9. Valve Opener 10. Water Level Sensor NOTE: Depending on humidifier model, the nebulizer may be different. Fig. 4 (Bottom of Water Tank) 11. Water Tank Valve 12.
TECHNICAL SPECIFICATIONS Rating Voltage Frequency Water Tank Capacity Output Per 24 Hours Run Time Per Tank Humidifying Capacity Noise 120V 60Hz Approx. 0.9 Gallon / 3.3 Liter Approx. 2.3 Gallon / 8.7 Liter Max. up to 24 hours / Min. 11 Hours Up to 250 sq. ft. / 23 m2 < 37 decibels from 3 feet away OPERATION AND USE BEFORE EACH USE CHECK HUMIDIFIER PLACEMENT Place the Humidifier on an elevated, non-metallic, lint-free, waterproof, level surface at least 2 feet above the floor.
ASSEMBLY ALWAYS use fresh cool water when operating the humidifier. 1. Turn Water Tank upside down and unscrew Water Tank Cap. NOTE: The opening next to the water tank cap is the mist channel. The mist channel is enclosed in plastic. The mist outlet channel is separate from the water in the water tank. See FIG. 4 #13 page 4. 2. Fill Water Tank with cool water. DO NOT fill water all the way to the rim. DO NOT CARRY FULL WATER TANK BY HANDLE. ALWAYS HOLD WATER TANK WITH TWO HANDS. DO NOT use hot water.
Note: The Power Indicator Light on the humidifier will remain on. The red light indicates that the humidifier is turned on and needs to be refilled. A NOTE ABOUT HUMIDITY It is best to keep the humidity level at about 40%-50% of relative humidity. In cold weather, windows and even some walls may fog or develop frost from excessive indoor humidity. If this occurs, reduce the mist output setting to avoid damage from condensed water dripping onto windowsills.
6. DO NOT place any heavy items on top of humidifier during storage as this may result in possible damage of the humidifier. 7. Store the cord in a clean, dry location away from metal objects. Always check the plug before use to ensure metal items have not become attached. TROUBLE SHOOTING DO NOT attempt to repair the motor or nebulizer yourself. If the humidifier continues to not operate please contact Crane Customer Care: 888-599-0992 or customer-service@crane-usa.com.
CUSTOMER CARE If you have any questions with regard to the operation of this humidifier or are in need of a spare part, please contact Crane Customer Care. Crane USA, Inc. 621 IL Route 83, Suite 202 Bensenville, Illinois 60106 Toll Free: 1-888-599-0992 (Monday - Friday 9:00am - 4:00pm CST) Email: customer-service@crane-usa.com Website: http://www.crane-usa.com NOTE: Spare Parts can also be purchased online at http://www.craneusa.com.
LIMITED WARRANTY Thank you for purchasing a Crane product. This Ultrasonic Humidifier was tested and meets our stringent quality standards. This product is warrantied to be free from manufacturing defects under normal use and conditions for 1 year. PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE. CALL US FOR PROBLEMS AND QUESTIONS. WE CAN HELP. If you experience unsatisfactory operation, first refer to the troubleshooting section in the manual to ensure that it is not due to care or cleaning.