Instruction manual

12
2. After you reach “CONF”, push the PGM Button again and use Up
and Down Arrows to navigate until you reach “PRO” in the bottom
display and push the “PGM” button again.
3. The display should now read “FNCT” in the bottom display and “2” in
the top display. You will need to change the “2” to “0”. To do that,
push the “PGM” button once and the “FNCT” should start flashing.
While it is flashing, use the Down Arrow to change the “2” to “0”.
When the “FNCT” stops flashing, push the exit button repeatedly to
return to normal display (Actual Value on Top and Setpoint Value on
Bottom.)
4. Now the control is setup as a Single Setpoint Control. Just use the
Down Arrows to change Setpoint Value.
EXAMPLE PROGRAM
Let’s say you want to have the oven to ramp up to 100°C in 30 minutes
and control for 1 hour at 100°C. Then you want to ramp up to 150° in 30
Minutes and control for 2 hours. Then you want to cool down to start Set
Point with Power Exhaust Outlet activated in one hour. See Graph:
EXAMPLE PROGRAM CHART
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
30 MINUTES INTERVALS
TEMPERATU
R
25
100 100
150 150 150 150
25
You would program the control like this:
STEP1 SP01=25° TPO01=00:30hr OC01-0000
STEP2 SP02=100° TPO02=01:00hr OC02-0000
STEP3 SP03=100° TPO03=00:30hr OC03-0000
STEP4 SP04=150° TPO04=02:00hr OC04-0000
STEP5 SP05=150° TPO05=01:00hr OC05-0100
STEP6 SP06=25° TPO06=00:00hr OC06-0000
The OC parameter 0100 is the value that activates the Exhaust Outlet on
the back of the oven.
To activate the program that is entered first return to normal display by
pushing the Exit Button repeatedly. After Normal Display is
reached, push the up arrow
once. The lower display should flash STrT