Instruction manual
17 
MECHANICAL 
Door not sealing 
  1/ check physical condition of gasket 
2/ assure that gasket is in original location 
Motor doesn't move 
  1/ if shaft spins freely: check connections to motor and check 
voltage to motor 
2/ if shaft rubs or is frozen, relieve binding and retest 
Motor makes noise 
1) Make sure that the fan or blower wheel is not contacting 
its housing. Adjust the motor mounting bracket position to 
re-center the fan or blower wheel, if necessary. 
2) Check the fan or blower wheel for damage or out of 
balance condition. Replace the fan or blower wheel if it is 
damaged or out of balance. 
3) Turn the motor shaft to make sure that it spins freely. If it 
binds or the bearings make a rubbing or scrapping sound 
then replace the motor.  
OTHER 
Controller on at all times - "locked-up"
  1/ Adjust set point to room temperature. If the light goes out 
but is still heating, replace the solid state relay. 
2/ turn unit off and on to reset 
3/ if cannot change any condition on the front panel, call 
Customer Service 
Controller timer resets on its own 
  1/ confirm that power from wall is consistent and within 
specs 
2/ call Customer Service with serial number 
Front panel displays are of
f
  1/ Check for wire damage. 
Unit or wall fuse/circuit breaker is 
blown 
  1/ check wall power source 
 2/ compare current draw and compare to specs on data plate 
3/ see what other loads are on the wall circuit 
Unit will not turn on 
  1/ check wall power source 
2/ check fuse/circuit breaker on unit or in wall 
3/ see if unit is on, e.g., fan or heater, and just controller is off 
4/ check all wiring connections, esp. around the on/off switch 
Unit is smoking 
–
out of box 
  1/ put unit under vent and run at full power for one hour. 
2/ follow special burn in procedures in section 6.0. 
Contamination in chambe
r
  1/ see cleaning procedure in operator’s manual 
2/ develop and follow SOP for specific application; include 
definition of cleaning technique and maintenance schedule 
Contamination in sample 
  1/ see “Contamination in chamber. 










