User manual

Table Of Contents
Option <6> FSI ACM Tilt and Compass
This option provides a scrolling display of FSI ACM tilt and compass information. The
scrolling display provides the operator with a hands free data steam during a spin test.
The firmware parses the response to extract tilt and compass measurements, displays the
result, and repeats the cycle until interrupted by the operator.
Scrolling
display
[CTRL]-[C]
stops scrolling
This option displays the ACM tilt (TX and TY)
and compass (HX, HY, and HZ) outputs for use
while mounting the ACM pressure housing.
<CTRL>-<C> to terminate display.
Applying power to ACM . . . ready.
TX TY HX HY HZ
+00.51 +01.12 +0.3460 -0.0051 -0.9382
+00.45 +01.31 +0.3464 -0.0038 -0.9381
+00.47 +01.16 +0.3467 -0.0025 -0.9380
+00.45 +01.26 +0.3470 -0.0018 -0.9379
+00.40 +01.27 +0.3473 -0.0017 -0.9378
+00.45 +01.18 +0.3470 -0.0017 -0.9379
+00.39 +01.30 +0.3470 -0.0030 -0.9378
+00.44 +01.21 +0.3468 -0.0035 -0.9379
+00.47 +01.26 +0.3465 -0.0031 -0.9380
+00.45 +01.30 +0.3459 -0.0047 -0.9383
+00.43 +01.23 +0.3468 -0.0044 -0.9379
Press any key to continue.
Figure 7-37: FSI ACM Tilt and Compass
System Evaluation
System Evaluation checks the drive motor, brake, and watchdog circuit.
Option <7> Motor Operation
This option tests the drive motor. The motor direction and duration of the velocity ramp
can be controlled for visual verification that the motor is spinning in the proper direction during
the test. A ramp duration of 30 seconds is recommended for a motor with load. A ramp duration
of a few seconds is sufficient for an unloaded motor.
7-25