Watchdog
resets TT8 and
restarts
system. Power-
up sequence
begins
Counter expires
Autonomous
recovery
begins
Steps in the
recovery
display as they
occur
Deployment
continues
03/21/2007 16:13:20 Sleeping until 03/21/2007 16:23:18 . . .
MMP-4_04
McLane Moored Profiler operator interface.
The MMP operating system is initialized
and running.
Type <CTRL>-<C> within 30 seconds to
assert operator control and complete
system initialization.
0 seconds
Setting watchdog clock . . . done.initialization successful.
Sizing flash card (~2 seconds / 100 Mbytes) . . . done.
521.347 Mbyte flash card installed
519.201 Mbyte currently free
File system can accommodate 4080 data files
RECOVERED XMIT INDEX - OldestProfileNotXmitted is: 0 . . .
RECOVERED XMIT INDEX - OldestProfileStored is: 0 . . .
Performing final initialization . . .
Unattended Deployment Preparation routine
successfully completed.
Continuing deployment.
3/21/2007 16:22:14
Initializing CTD logging pointers . . .
Figure 7-45: Watchdog Reset URAO (screen 2 of 2)
IMPORTANT
Do not pre-program the MMP and then, at a later date, connect the battery and launch the
profiler without further operator interaction. When URAO is triggered, it assumes that the
MMP is in the water and that the mooring is fully deployed. Profiling typically starts less than
3 minutes after the battery is connected.
System Options Tests
System Options Tests check functions of other enabled options such as the underwater
inductive modem (UIM), fluorometer and turbidity sensors. A battery endurance estimate can
also be viewed.
7-30