Option <C> Configure
The System Configuration menu contains system parameters and sensor selections. This
menu prevents sensor selections that are mutually exclusive. Confirm that the correct sensor and
parameters are configured.
Mutually
exclusive
selections are
prevented
╔═════════════════════════════════╗
System Configuration
╚═════════════════════════════════╝
System Parameters:
<E> Nominal Endurance 240 Ah
<I> Inductive Telemetry Disabled
<T> Acoustic Transponder Disabled
<C> Inductive Charger Modem Disabled
<F> File Deletion Disabled
Sensor Suite:
<1> FSI EM CTD Disabled
<2> SeaBird 41CP CTD Enabled
<3> SeaBird 52MP CTD Disabled
<4> FSI 2D ACM Disabled
<5> Nobska MAVS ACM Disabled
<6> SeaPoint Fluorometer Disabled (Chlorophyll à)
<7> Wetlabs Fluorometer Disabled
<8> SeaPoint Turbidity Disabled (IR)
Exit:
<X> Save Changes and Exit
Selection ? 1
Enable FSI EM CTD (Yes/No) [Y] ? y
Disabling alternate CTDs.
Figure 7-56: System Configuration Menu
NOTE
The L24-1000 battery has 240Ah of battery energy. Battery energy is used to calculate the
estimated battery expiration. The battery energy used in the calculation can be changed by
selecting <E>.
Selection ? e
The battery energy is: 240 Ah
Enter nominal battery endurance [Ah] (10 to 1000) ? 500
Figure 7-57: <E> Change Nominal Battery Endurance
7-36