If continuous profiling is selected, the profile consistency check is not performed.
The MPD is compared to the profile start interval. If the programmed start interval is
shorter than the MPD the operator will be prompted to change the selections. The operator may
choose to disregard the warning and proceed, thus accepting the risk of skipped profiles (or
bursts) during the deployment.
For example, the pair start interval in the ongoing deployment example was reduced from
6 hours to 3 hours to trigger the warning.
Calculated pair
duration
System alerts
operator
Checking entries . . . done.
All entries are within allowed ranges.
Checking profile schedule . . . done.
Calculated minimum profile pair duration: 05:02:08
Estimated minimum profile pair duration exceeds pair
start interval. System will skip pairs whenever a
pair start time is missed.
Change selections (Yes/No) [Y] ?
Figure 7-71: Profile Consistency Check
NOTE
If burst mode is disabled (profiles/pairs per burst set to 1) or if continuous bursts are selected
(burst interval set to 00 00:00:00), no burst consistency check is performed.
When burst mode is enabled and the burst interval is not zero, the firmware compares the
minimum burst duration with the burst interval which is one of:
MPD × profiles per burst if continuous profiling is enabled
start interval × profiles per burst if MPD < a non-zero start interval
[MPD / start interval] × profiles per burst if MPD a non-zero start interval