User manual

Table Of Contents
Sample File-Single Profile - All Data Files
The sample shown next illustrates a display for a single profile (Profile 3) when ‘Single
Profile’ and ‘All data files’ are selected. This example shows the Profile data with the FSI CTD
and ACM installed.
Engineering
data
Sensor and
motion start
times
System logs
0.000 for
pressure during
velocity ramp,
CTD not
queried
First stop
check after
velocity ramp
Velocity ramp
and profile exit
conditions
Sensor and
motion stop
times
Stream serial data from:
<D> Deployment
<S> Single profile
<R> Range of profiles
<L> Logging files
Exit to:
<M> Main menu
Selection ? S
Select data files to download:
<1> All data files
<2> Engineering data files only
<3> CTD data files only
<4> ACM data files only
Selection ? 1
Enter ID# of profile to be read: (0 to 560) ? 3
Profile 3
ENGINEERING DATA
________________
Opening file E0000000.dat, engineering data for
profile 3 of 560.
Profile 3
Sensors were turned on at 11/24/2006 13:58:20
Vehicle began profiling at 11/24/2006 14:00:01
Date Time [mA] [V] [dbar] Fluor[mV] Gain Turb[mV] Gain
11/24/2006 14:00:03 81 12.0 0.000 99.00
11/24/2006 14:00:07 129 11.9 0.000
11/24/2006 14:00:11 222 11.8 0.000
11/24/2006 14:00:15 253 11.7 0.000
11/24/2006 14:00:19 238 11.7 0.000
11/24/2006 14:00:34 199 11.8 8.002
11/24/2006 14:00:38 192 11.8 6.829
Ramp exit: SMOOTH RUNNING
Profile exit: TOP PRESSURE
Vehicle motion stopped at 11/24/2006 14:00:53
Sensor logging stopped at 11/24/2006 14:02:55
Figure 7-83: Stream Serial Data From Single Profile
7-68