User manual

Table Of Contents
<W> Watchdog Initialization
If the automatic watchdog initialization fails during the power-up sequence, select this
hidden option from the Main Menu. Typing ‘W’ or ‘w’ commands the firmware to re-initialize
the watchdog, provides a prompt to reset the RTC, and synchronizes the WDC.
The MMP cannot be deployed if the watchdog is not functioning properly and
communicating cleanly with the firmware. Therefore, all watchdog operations (automatic and
operator initiated, including deploying the profiler), are locked out until the watchdog is
successfully initialized.
Selection ? w
Independent system watchdog successfully initialized.
Watchdog alarm IRQ has been activated.
Clock reads 01/30/2006 12:04:16
Change time & date (Yes/No) [N] ? y
Enter date as MM DD YY HH MM SS
Enter year 2001 as 1, 01, 101, or 2001
Enter correct time [01/30/2002 12:04:19] ? 1 30 2002 12 4 35
Clock reads 01/30/106 12:04:35
Change time & date (Yes/No) [N] ?
Setting watchdog clock . . . done.
Figure 7-94: Re-initialize System Watchdog
<O> Profiling History
Profiling history is tracked as motor hours and total meters traveled. Typing 'O' or 'o'
from the Main Menu displays this information.
Selection ? o
Profiling history:
Total motor hours: 15.33 hours
Total meters traveled: 8456 meters
Figure 7-95: Profiling Odometer
<Q> Exiting to the Monitor
To exit to the monitor, at the Main Menu type ‘q’ or ‘Q’ followed by [ENTER]. A
password prompt will display. Type mclane (no quotes, all lower case), and press [ENTER] to
7-77