User manual

Table Of Contents
Welcome to the McLane Moored Profiler
system initialization.
512.066 Mbyte flash card installed
File system can accommodate 4091 data files
Step
ì System
initialization
countdown
Step
í
Watchdog
activation
Step
î Flash
card sizing
Step
ï Setting
RTC
[ENTER] sets
RTC
System syncs
WDC
Step
ð
Profiling
odometer
& trip meter
MMP-3_12
operator interface. The MMP operating
system is initialized and running.
Type <CTRL>-<C> within 30 seconds to
assert operator control and complete
30 seconds
29 seconds
28 seconds
Independent system watchdog successfully initialized.
Watchdog alarm IRQ has been activated.
Sizing flash card (~2 seconds / 100 Mbytes) . . . done.
475.988 Mbyte currently free
Deployment can include up to 1361 file sets
Clock reads 01/01/1970 00:00:09
Change time & date (Yes/No) [N] ? y
Enter date as MM DD YY HH MM SS
Enter year 2001 as 1, 01, 101, or 2001
Enter correct time [01/01/1970 00:00:18] ? 12 29 04 12 02 45
Clock reads 12/29/2004 12:02:45
Change time & date (Yes/No) [N] ?
Setting watchdog clock . . . done.
Profiling odometer
Total profiling distance: 12458 meters
Battery trip meter: 12425 meters
Reset trip meter (new battery) (Yes/No) [N] ? n
Figure G-1: Power Up Sequence
The MMP Main Menu displays once initialization is complete. The operator initiates all
further system operations from the Main Menu.
G-3