Re-Booting the System
The power-up sequence does not repeat unless the system is re-booted. Execute a “cold”
re-boot by disconnecting the power and then reconnecting it after 5 to 10 seconds. The delay
allows capacitors in the system to fully discharge. Execute a “warm” re-boot , which will not
reset the RTC, by exiting the firmware to the TT8v2 monitor (TOM8) and then manually re-
starting the program.
System Prompts and Key Combinations
McLane recommends the use of the file capture utility within the communications
program to log interactions with the MMP. A complete record of the deployment programming
steps can be invaluable during data analysis.
Following is some information about system prompts and key combinations that are
frequently used with the system:
Upper and lower case alphabetic characters are used for most system prompts, however,
the password prompt to exit to the monitor is case sensitive.
Select the default choice for many prompts by pressing [ENTER]. If a default is available,
the system displays the value at the end of the prompt in square brackets.
Prompts for numerical values accept only numbers that fall within a displayed range.
When an out of range or otherwise unacceptable entry is made the system re-prompts the
operator.
Prompts for alphanumeric input accept only characters from the displayed list.
Unrecognized characters cause the system to re-prompt the operator.
[CTRL]-[C] terminates the current operation and returns you to the Main Menu.
[CTRL]-[C] terminates a deployment after the profiler is recovered. The system will
complete any critical steps, such as terminal data storage operations, and then return to the
Main Menu.
[CTRL]-[C] wakes the system from the low power sleep condition.
Using the File Capture Utility