The program parses the response to extract tilt and compass measurements, displays the
result, and repeats the cycle until interrupted by the operator.
[CTRL]-[C]
stops scrolling
+00.51 +01.12 +0.3460 -0.0051 -0.9382
Scrolling
display
This option displays the ACM tilt (TX and TY)
and compass (HX, HY, and HZ) outputs for use
while mounting the ACM pressure housing.
<CTRL>-<C> to terminate display.
Applying power to ACM . . . ready.
TX TY HX HY HZ
+00.45 +01.31 +0.3464 -0.0038 -0.9381
+00.47 +01.16 +0.3467 -0.0025 -0.9380
+00.45 +01.26 +0.3470 -0.0018 -0.9379
+00.40 +01.27 +0.3473 -0.0017 -0.9378
+00.45 +01.18 +0.3470 -0.0017 -0.9379
+00.39 +01.30 +0.3470 -0.0030 -0.9378
+00.44 +01.21 +0.3468 -0.0035 -0.9379
+00.47 +01.26 +0.3465 -0.0031 -0.9380
+00.45 +01.30 +0.3459 -0.0047 -0.9383
+00.43 +01.23 +0.3468 -0.0044 -0.9379
Press any key to continue.
Figure G-3 : ACM Tilt and Compass 0
Option <7> Motor Operation
This option tests the drive motor. The operator can control the motor direction and
duration of the velocity ramp. Visually verify that the motor is spinning in the proper direction
when you conduct this test. A ramp duration of 30 seconds is recommended for a motor with
load. A ramp duration of a few seconds is sufficient for an unloaded motor. A scrolling display
of date and time, motor current, and battery voltage is provided once the motor reaches full speed.
The operator can stop the motor abruptly or with a velocity down ramp. The motor is
automatically disabled and the brake set once the motor is stopped. An example is shown next.
G-24