Top and Bottom Faired End Caps
To access the electronics housing, remove the bottom end cap. First, lay the profiler on
its right side. Then unscrew and remove the socket head nylon cap screw that secures the end
cap. The screw is located in the opening at the bottom of the seam where the two halves of the
skin meet. The cap screw is finger-tight.
NOTE
Elevate the lower end of the MMP slightly when removing or replacing the end cap and place a
support under a rib so that the load is not entirely on the skin.
Figure 2-4: Unscrewing the Nylon Cap Screw
With the screw removed, strike the front of the end cap sharply with your palm to slide
the assembly back and off its four 316 stainless steel mounting posts. Reverse the procedure to
reattach the end cap. The end cap will remain attached to the frame by a short loop of rope. The
rope can be used for a tending line during launch and recovery at sea.