User manual

Table Of Contents
2. Select <F> ‘File Deletion’.
╔═════════════════════════════════╗
System Configuration
╚═════════════════════════════════╝
System Parameters:
<E> Nominal Endurance 1.0 million meters
<I> Inductive Telemetry Enabled
<T> Acoustic Transponder Disabled
<F> File Deletion Enabled
Sensor Suite:
<1> FSI EM CTD Disabled
<2> SeaBird 41CP CTD Disabled
<3> SeaBird 52MP CTD Enabled
<4> FSI 2D ACM Disabled
<5> Nobska MAVS3 ACM Disabled
<6> SeaPoint Fluorometer Disabled (Chlorophyll α)
<7> SeaPoint Turbidity Disabled (IR)
Exit:
<X> Save Changes and Exit
Selection ? f
Enable file deletion (Yes/No) [N] ? y
Enter maximum number of profiles to store: ( 0 to 60) ? 5
Selection ? x
Storing system configuration changes . . . done.
Figure J-2: Enabling File Deletion and Profiles to Store
3. Type ‘y’ to enable file deletion
4. Enter the number of profiles to store (up to 60).
5. Type ‘x’ to exit and save changes.
Appendix J-10